	get options in config_example.py reachable
Some options in config_example.py are not reachable. It makes users confused. So make the options in the file as gobal_alias. Signed-off-by: zhizhou.zhang <zhizhou.zhang@spreadtrum.com>
This commit is contained in:
		| @@ -92,33 +92,42 @@ class Daq(Instrument): | ||||
|  | ||||
|     parameters = [ | ||||
|         Parameter('server_host', kind=str, default='localhost', | ||||
|                   global_alias='daq_server_host', | ||||
|                   description='The host address of the machine that runs the daq Server which the ' | ||||
|                               'insturment communicates with.'), | ||||
|         Parameter('server_port', kind=int, default=56788, | ||||
|                   global_alias='daq_server_port', | ||||
|                   description='The port number for daq Server in which daq insturment communicates ' | ||||
|                               'with.'), | ||||
|         Parameter('device_id', kind=str, default='Dev1', | ||||
|                   global_alias='daq_device_id', | ||||
|                   description='The ID under which the DAQ is registered with the driver.'), | ||||
|         Parameter('v_range', kind=float, default=2.5, | ||||
|                   global_alias='daq_v_range', | ||||
|                   description='Specifies the voltage range for the SOC voltage channel on the DAQ ' | ||||
|                               '(please refer to :ref:`daq_setup` for details).'), | ||||
|         Parameter('dv_range', kind=float, default=0.2, | ||||
|                   global_alias='daq_dv_range', | ||||
|                   description='Specifies the voltage range for the resistor voltage channel on ' | ||||
|                               'the DAQ (please refer to :ref:`daq_setup` for details).'), | ||||
|         Parameter('sampling_rate', kind=int, default=10000, | ||||
|                   global_alias='daq_sampling_rate', | ||||
|                   description='DAQ sampling rate. DAQ will take this many samples each ' | ||||
|                               'second. Please note that this maybe limitted by your DAQ model ' | ||||
|                               'and then number of ports you\'re measuring (again, see ' | ||||
|                               ':ref:`daq_setup`)'), | ||||
|         Parameter('resistor_values', kind=list, mandatory=True, | ||||
|                   global_alias='daq_resistor_values', | ||||
|                   description='The values of resistors (in Ohms) across which the voltages are measured on ' | ||||
|                               'each port.'), | ||||
|         Parameter('channel_map', kind=list_of_ints, default=(0, 1, 2, 3, 4, 5, 6, 7, 16, 17, 18, 19, 20, 21, 22, 23), | ||||
|                   global_alias='daq_channel_map', | ||||
|                   description='Represents mapping from  logical AI channel number to physical ' | ||||
|                               'connector on the DAQ (varies between DAQ models). The default ' | ||||
|                               'assumes DAQ 6363 and similar with AI channels on connectors ' | ||||
|                               '0-7 and 16-23.'), | ||||
|         Parameter('labels', kind=list_of_strs, | ||||
|                   global_alias='daq_labels', | ||||
|                   description='List of port labels. If specified, the lenght of the list must match ' | ||||
|                               'the length of ``resistor_values``. Defaults to "PORT_<pnum>", where ' | ||||
|                               '"pnum" is the number of the port.') | ||||
|   | ||||
		Reference in New Issue
	