1
0
mirror of https://github.com/ARM-software/workload-automation.git synced 2025-01-18 20:11:20 +00:00

get options in config_example.py reachable

Some options in config_example.py are not reachable. It makes users
confused. So make the options in the file as gobal_alias.

Signed-off-by: zhizhou.zhang <zhizhou.zhang@spreadtrum.com>
This commit is contained in:
zhizhou.zhang 2015-06-04 15:50:23 +08:00
parent 3044d192f9
commit 7422a72a7b
5 changed files with 17 additions and 12 deletions

View File

@ -198,18 +198,6 @@ logging = {
# The kinds of sensors hwmon instrument will look for
#hwmon_sensors = ['energy', 'temp']
####################################################################################################
##################################### streamline configuration #####################################
# The port number on which gatord will listen
#port = 8080
# Enabling/disabling the run of 'streamline -analyze' on the captured data.
#streamline_analyze = True
# Enabling/disabling the generation of a CSV report
#streamline_report_csv = True
####################################################################################################
###################################### trace-cmd configuration #####################################

View File

@ -92,33 +92,42 @@ class Daq(Instrument):
parameters = [
Parameter('server_host', kind=str, default='localhost',
global_alias='daq_server_host',
description='The host address of the machine that runs the daq Server which the '
'insturment communicates with.'),
Parameter('server_port', kind=int, default=56788,
global_alias='daq_server_port',
description='The port number for daq Server in which daq insturment communicates '
'with.'),
Parameter('device_id', kind=str, default='Dev1',
global_alias='daq_device_id',
description='The ID under which the DAQ is registered with the driver.'),
Parameter('v_range', kind=float, default=2.5,
global_alias='daq_v_range',
description='Specifies the voltage range for the SOC voltage channel on the DAQ '
'(please refer to :ref:`daq_setup` for details).'),
Parameter('dv_range', kind=float, default=0.2,
global_alias='daq_dv_range',
description='Specifies the voltage range for the resistor voltage channel on '
'the DAQ (please refer to :ref:`daq_setup` for details).'),
Parameter('sampling_rate', kind=int, default=10000,
global_alias='daq_sampling_rate',
description='DAQ sampling rate. DAQ will take this many samples each '
'second. Please note that this maybe limitted by your DAQ model '
'and then number of ports you\'re measuring (again, see '
':ref:`daq_setup`)'),
Parameter('resistor_values', kind=list, mandatory=True,
global_alias='daq_resistor_values',
description='The values of resistors (in Ohms) across which the voltages are measured on '
'each port.'),
Parameter('channel_map', kind=list_of_ints, default=(0, 1, 2, 3, 4, 5, 6, 7, 16, 17, 18, 19, 20, 21, 22, 23),
global_alias='daq_channel_map',
description='Represents mapping from logical AI channel number to physical '
'connector on the DAQ (varies between DAQ models). The default '
'assumes DAQ 6363 and similar with AI channels on connectors '
'0-7 and 16-23.'),
Parameter('labels', kind=list_of_strs,
global_alias='daq_labels',
description='List of port labels. If specified, the lenght of the list must match '
'the length of ``resistor_values``. Defaults to "PORT_<pnum>", where '
'"pnum" is the number of the port.')

View File

@ -63,6 +63,7 @@ class HwmonInstrument(Instrument):
parameters = [
Parameter('sensors', kind=list_of_strs, default=['energy', 'temp'],
global_alias='hwmon_sensors',
description='The kinds of sensors hwmon instrument will look for')
]

View File

@ -69,15 +69,18 @@ class PerfInstrument(Instrument):
parameters = [
Parameter('events', kind=list_of_strs, default=['migrations', 'cs'],
global_alias='perf_events',
constraint=(lambda x: x, 'must not be empty.'),
description="""Specifies the events to be counted."""),
Parameter('optionstring', kind=arguments, default='-a',
global_alias='perf_options',
description="""Specifies options to be used for the perf command. This
may be a list of option strings, in which case, multiple instances of perf
will be kicked off -- one for each option string. This may be used to e.g.
collected different events from different big.LITTLE clusters.
"""),
Parameter('labels', kind=list_of_strs, default=None,
global_alias='perf_labels',
description="""Provides labels for pref output. If specified, the number of
labels must match the number of ``optionstring``\ s.
"""),

View File

@ -60,6 +60,7 @@ class CciPmuLogger(Instrument):
parameters = [
Parameter('events', kind=list, default=DEFAULT_EVENTS,
global_alias='cci_pmu_events',
description="""
A list of strings, each representing an event to be counted. The length
of the list cannot exceed the number of PMU counters available (4 in CCI-400).
@ -67,14 +68,17 @@ class CciPmuLogger(Instrument):
clusters will be counted by default. E.g. ``['0x63', '0x83']``.
"""),
Parameter('event_labels', kind=list, default=[],
global_alias='cci_pmu_event_labels',
description="""
A list of labels to be used when reporting PMU counts. If specified,
this must be of the same length as ``cci_pmu_events``. If not specified,
events will be labeled "event_<event_number>".
"""),
Parameter('period', kind=int, default=10,
global_alias='cci_pmu_period',
description='The period (in jiffies) between counter reads.'),
Parameter('install_module', kind=boolean, default=True,
global_alias='cci_pmu_install_module',
description="""
Specifies whether pmu_logger has been compiled as a .ko module that needs
to be installed by the instrument. (.ko binary must be in {}). If this is set