mirror of
https://github.com/ARM-software/workload-automation.git
synced 2025-01-18 20:11:20 +00:00
get options in config_example.py reachable
Some options in config_example.py are not reachable. It makes users confused. So make the options in the file as gobal_alias. Signed-off-by: zhizhou.zhang <zhizhou.zhang@spreadtrum.com>
This commit is contained in:
parent
3044d192f9
commit
7422a72a7b
@ -198,18 +198,6 @@ logging = {
|
||||
# The kinds of sensors hwmon instrument will look for
|
||||
#hwmon_sensors = ['energy', 'temp']
|
||||
|
||||
####################################################################################################
|
||||
##################################### streamline configuration #####################################
|
||||
|
||||
# The port number on which gatord will listen
|
||||
#port = 8080
|
||||
|
||||
# Enabling/disabling the run of 'streamline -analyze' on the captured data.
|
||||
#streamline_analyze = True
|
||||
|
||||
# Enabling/disabling the generation of a CSV report
|
||||
#streamline_report_csv = True
|
||||
|
||||
####################################################################################################
|
||||
###################################### trace-cmd configuration #####################################
|
||||
|
||||
|
@ -92,33 +92,42 @@ class Daq(Instrument):
|
||||
|
||||
parameters = [
|
||||
Parameter('server_host', kind=str, default='localhost',
|
||||
global_alias='daq_server_host',
|
||||
description='The host address of the machine that runs the daq Server which the '
|
||||
'insturment communicates with.'),
|
||||
Parameter('server_port', kind=int, default=56788,
|
||||
global_alias='daq_server_port',
|
||||
description='The port number for daq Server in which daq insturment communicates '
|
||||
'with.'),
|
||||
Parameter('device_id', kind=str, default='Dev1',
|
||||
global_alias='daq_device_id',
|
||||
description='The ID under which the DAQ is registered with the driver.'),
|
||||
Parameter('v_range', kind=float, default=2.5,
|
||||
global_alias='daq_v_range',
|
||||
description='Specifies the voltage range for the SOC voltage channel on the DAQ '
|
||||
'(please refer to :ref:`daq_setup` for details).'),
|
||||
Parameter('dv_range', kind=float, default=0.2,
|
||||
global_alias='daq_dv_range',
|
||||
description='Specifies the voltage range for the resistor voltage channel on '
|
||||
'the DAQ (please refer to :ref:`daq_setup` for details).'),
|
||||
Parameter('sampling_rate', kind=int, default=10000,
|
||||
global_alias='daq_sampling_rate',
|
||||
description='DAQ sampling rate. DAQ will take this many samples each '
|
||||
'second. Please note that this maybe limitted by your DAQ model '
|
||||
'and then number of ports you\'re measuring (again, see '
|
||||
':ref:`daq_setup`)'),
|
||||
Parameter('resistor_values', kind=list, mandatory=True,
|
||||
global_alias='daq_resistor_values',
|
||||
description='The values of resistors (in Ohms) across which the voltages are measured on '
|
||||
'each port.'),
|
||||
Parameter('channel_map', kind=list_of_ints, default=(0, 1, 2, 3, 4, 5, 6, 7, 16, 17, 18, 19, 20, 21, 22, 23),
|
||||
global_alias='daq_channel_map',
|
||||
description='Represents mapping from logical AI channel number to physical '
|
||||
'connector on the DAQ (varies between DAQ models). The default '
|
||||
'assumes DAQ 6363 and similar with AI channels on connectors '
|
||||
'0-7 and 16-23.'),
|
||||
Parameter('labels', kind=list_of_strs,
|
||||
global_alias='daq_labels',
|
||||
description='List of port labels. If specified, the lenght of the list must match '
|
||||
'the length of ``resistor_values``. Defaults to "PORT_<pnum>", where '
|
||||
'"pnum" is the number of the port.')
|
||||
|
@ -63,6 +63,7 @@ class HwmonInstrument(Instrument):
|
||||
|
||||
parameters = [
|
||||
Parameter('sensors', kind=list_of_strs, default=['energy', 'temp'],
|
||||
global_alias='hwmon_sensors',
|
||||
description='The kinds of sensors hwmon instrument will look for')
|
||||
]
|
||||
|
||||
|
@ -69,15 +69,18 @@ class PerfInstrument(Instrument):
|
||||
|
||||
parameters = [
|
||||
Parameter('events', kind=list_of_strs, default=['migrations', 'cs'],
|
||||
global_alias='perf_events',
|
||||
constraint=(lambda x: x, 'must not be empty.'),
|
||||
description="""Specifies the events to be counted."""),
|
||||
Parameter('optionstring', kind=arguments, default='-a',
|
||||
global_alias='perf_options',
|
||||
description="""Specifies options to be used for the perf command. This
|
||||
may be a list of option strings, in which case, multiple instances of perf
|
||||
will be kicked off -- one for each option string. This may be used to e.g.
|
||||
collected different events from different big.LITTLE clusters.
|
||||
"""),
|
||||
Parameter('labels', kind=list_of_strs, default=None,
|
||||
global_alias='perf_labels',
|
||||
description="""Provides labels for pref output. If specified, the number of
|
||||
labels must match the number of ``optionstring``\ s.
|
||||
"""),
|
||||
|
@ -60,6 +60,7 @@ class CciPmuLogger(Instrument):
|
||||
|
||||
parameters = [
|
||||
Parameter('events', kind=list, default=DEFAULT_EVENTS,
|
||||
global_alias='cci_pmu_events',
|
||||
description="""
|
||||
A list of strings, each representing an event to be counted. The length
|
||||
of the list cannot exceed the number of PMU counters available (4 in CCI-400).
|
||||
@ -67,14 +68,17 @@ class CciPmuLogger(Instrument):
|
||||
clusters will be counted by default. E.g. ``['0x63', '0x83']``.
|
||||
"""),
|
||||
Parameter('event_labels', kind=list, default=[],
|
||||
global_alias='cci_pmu_event_labels',
|
||||
description="""
|
||||
A list of labels to be used when reporting PMU counts. If specified,
|
||||
this must be of the same length as ``cci_pmu_events``. If not specified,
|
||||
events will be labeled "event_<event_number>".
|
||||
"""),
|
||||
Parameter('period', kind=int, default=10,
|
||||
global_alias='cci_pmu_period',
|
||||
description='The period (in jiffies) between counter reads.'),
|
||||
Parameter('install_module', kind=boolean, default=True,
|
||||
global_alias='cci_pmu_install_module',
|
||||
description="""
|
||||
Specifies whether pmu_logger has been compiled as a .ko module that needs
|
||||
to be installed by the instrument. (.ko binary must be in {}). If this is set
|
||||
|
Loading…
x
Reference in New Issue
Block a user