energy_model: minor fix for previous adjustment.

This commit is contained in:
Sergei Trofimov 2015-09-03 11:06:26 +01:00
parent c04b98c75a
commit 0179d45b5b

View File

@ -307,7 +307,7 @@ def get_cpus_power_table(data, index, opps, leak_factors): # pylint: disable=to
bs_power_table.loc[bs_power_table[cluster, 1].notnull(), (cluster, 0)] = \
(2 * power_table[cluster, 1] - power_table[cluster, 2]).values
else:
leakage = leak_factors[cluster] * 2 * (opps['voltage'] / 1000000)**3 / 0.9**3
leakage = leak_factors[cluster] * 2 * (opps[cluster]['voltage'] / 1000000)**3 / 0.9**3
leakage_delta = leakage - leakage[0]
bs_power_table.loc[bs_power_table[cluster, 1].notnull(), (cluster, 0)] = \
(2 * power_table[cluster, 1] + leakage_delta - power_table[cluster, 2]).values
@ -406,9 +406,9 @@ class EnergyModelInstrument(Instrument):
description="""The number of frequencies begining from the highest, to be adjusted for
the thermal effect."""),
Parameter('big_opps', kind=opp_table,
description="""OPP table mapping frequency to volatage (kHz --> mV) for the big cluster."""),
description="""OPP table mapping frequency to voltage (kHz --> mV) for the big cluster."""),
Parameter('little_opps', kind=opp_table,
description="""OPP table mapping frequency to volatage (kHz --> mV) for the little cluster."""),
description="""OPP table mapping frequency to voltage (kHz --> mV) for the little cluster."""),
Parameter('big_leakage', kind=int, default=120,
description="""
Leakage factor for the big cluster (this is specific to a particular core implementation).