import esphome.codegen as cg
|
|
import esphome.config_validation as cv
|
|
from esphome.components import sensor, spi
|
|
from esphome.const import (
|
|
CONF_ID,
|
|
CONF_REACTIVE_POWER,
|
|
CONF_VOLTAGE,
|
|
CONF_CURRENT,
|
|
CONF_POWER,
|
|
CONF_POWER_FACTOR,
|
|
CONF_FREQUENCY,
|
|
CONF_FORWARD_ACTIVE_ENERGY,
|
|
CONF_REVERSE_ACTIVE_ENERGY,
|
|
DEVICE_CLASS_CURRENT,
|
|
DEVICE_CLASS_ENERGY,
|
|
DEVICE_CLASS_POWER,
|
|
DEVICE_CLASS_POWER_FACTOR,
|
|
DEVICE_CLASS_VOLTAGE,
|
|
ICON_LIGHTBULB,
|
|
ICON_CURRENT_AC,
|
|
STATE_CLASS_MEASUREMENT,
|
|
STATE_CLASS_TOTAL_INCREASING,
|
|
UNIT_HERTZ,
|
|
UNIT_VOLT,
|
|
UNIT_AMPERE,
|
|
UNIT_WATT,
|
|
UNIT_VOLT_AMPS_REACTIVE,
|
|
UNIT_WATT_HOURS,
|
|
)
|
|
|
|
CONF_LINE_FREQUENCY = "line_frequency"
|
|
CONF_METER_CONSTANT = "meter_constant"
|
|
CONF_PL_CONST = "pl_const"
|
|
CONF_GAIN_PGA = "gain_pga"
|
|
CONF_GAIN_METERING = "gain_metering"
|
|
CONF_GAIN_VOLTAGE = "gain_voltage"
|
|
CONF_GAIN_CT = "gain_ct"
|
|
LINE_FREQS = {
|
|
"50HZ": 50,
|
|
"60HZ": 60,
|
|
}
|
|
PGA_GAINS = {
|
|
"1X": 0x4,
|
|
"4X": 0x0,
|
|
"8X": 0x1,
|
|
"16X": 0x2,
|
|
"24X": 0x3,
|
|
}
|
|
|
|
atm90e26_ns = cg.esphome_ns.namespace("atm90e26")
|
|
ATM90E26Component = atm90e26_ns.class_(
|
|
"ATM90E26Component", cg.PollingComponent, spi.SPIDevice
|
|
)
|
|
|
|
CONFIG_SCHEMA = (
|
|
cv.Schema(
|
|
{
|
|
cv.GenerateID(): cv.declare_id(ATM90E26Component),
|
|
cv.Optional(CONF_VOLTAGE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_VOLT,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_VOLTAGE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_CURRENT): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_AMPERE,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_CURRENT,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_POWER): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_POWER,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_REACTIVE_POWER): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_VOLT_AMPS_REACTIVE,
|
|
icon=ICON_LIGHTBULB,
|
|
accuracy_decimals=2,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_POWER_FACTOR): sensor.sensor_schema(
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_POWER_FACTOR,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_FORWARD_ACTIVE_ENERGY): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT_HOURS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_ENERGY,
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
),
|
|
cv.Optional(CONF_REVERSE_ACTIVE_ENERGY): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT_HOURS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_ENERGY,
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
),
|
|
cv.Optional(CONF_FREQUENCY): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_HERTZ,
|
|
icon=ICON_CURRENT_AC,
|
|
accuracy_decimals=1,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Required(CONF_LINE_FREQUENCY): cv.enum(LINE_FREQS, upper=True),
|
|
cv.Required(CONF_METER_CONSTANT): cv.positive_float,
|
|
cv.Optional(CONF_PL_CONST, default=1429876): cv.uint32_t,
|
|
cv.Optional(CONF_GAIN_METERING, default=7481): cv.uint16_t,
|
|
cv.Optional(CONF_GAIN_VOLTAGE, default=26400): cv.int_range(
|
|
min=0, max=32767
|
|
),
|
|
cv.Optional(CONF_GAIN_CT, default=31251): cv.uint16_t,
|
|
cv.Optional(CONF_GAIN_PGA, default="1X"): cv.enum(PGA_GAINS, upper=True),
|
|
}
|
|
)
|
|
.extend(cv.polling_component_schema("60s"))
|
|
.extend(spi.spi_device_schema())
|
|
)
|
|
|
|
|
|
async def to_code(config):
|
|
var = cg.new_Pvariable(config[CONF_ID])
|
|
await cg.register_component(var, config)
|
|
await spi.register_spi_device(var, config)
|
|
|
|
if voltage_config := config.get(CONF_VOLTAGE):
|
|
sens = await sensor.new_sensor(voltage_config)
|
|
cg.add(var.set_voltage_sensor(sens))
|
|
if current_config := config.get(CONF_CURRENT):
|
|
sens = await sensor.new_sensor(current_config)
|
|
cg.add(var.set_current_sensor(sens))
|
|
if power_config := config.get(CONF_POWER):
|
|
sens = await sensor.new_sensor(power_config)
|
|
cg.add(var.set_power_sensor(sens))
|
|
if reactive_power_config := config.get(CONF_REACTIVE_POWER):
|
|
sens = await sensor.new_sensor(reactive_power_config)
|
|
cg.add(var.set_reactive_power_sensor(sens))
|
|
if power_factor_config := config.get(CONF_POWER_FACTOR):
|
|
sens = await sensor.new_sensor(power_factor_config)
|
|
cg.add(var.set_power_factor_sensor(sens))
|
|
if forward_active_energy_config := config.get(CONF_FORWARD_ACTIVE_ENERGY):
|
|
sens = await sensor.new_sensor(forward_active_energy_config)
|
|
cg.add(var.set_forward_active_energy_sensor(sens))
|
|
if reverse_active_energy_config := config.get(CONF_REVERSE_ACTIVE_ENERGY):
|
|
sens = await sensor.new_sensor(reverse_active_energy_config)
|
|
cg.add(var.set_reverse_active_energy_sensor(sens))
|
|
if frequency_config := config.get(CONF_FREQUENCY):
|
|
sens = await sensor.new_sensor(frequency_config)
|
|
cg.add(var.set_freq_sensor(sens))
|
|
cg.add(var.set_line_freq(config[CONF_LINE_FREQUENCY]))
|
|
cg.add(var.set_meter_constant(config[CONF_METER_CONSTANT]))
|
|
cg.add(var.set_pl_const(config[CONF_PL_CONST]))
|
|
cg.add(var.set_gain_metering(config[CONF_GAIN_METERING]))
|
|
cg.add(var.set_gain_voltage(config[CONF_GAIN_VOLTAGE]))
|
|
cg.add(var.set_gain_ct(config[CONF_GAIN_CT]))
|
|
cg.add(var.set_gain_pga(config[CONF_GAIN_PGA]))
|