import esphome.codegen as cg import esphome.config_validation as cv from esphome.components import sensor, spi from esphome.const import ( CONF_ID, CONF_REACTIVE_POWER, CONF_VOLTAGE, CONF_CURRENT, CONF_POWER, CONF_POWER_FACTOR, CONF_FREQUENCY, CONF_FORWARD_ACTIVE_ENERGY, CONF_REVERSE_ACTIVE_ENERGY, DEVICE_CLASS_CURRENT, DEVICE_CLASS_ENERGY, DEVICE_CLASS_POWER, DEVICE_CLASS_POWER_FACTOR, DEVICE_CLASS_VOLTAGE, ICON_LIGHTBULB, ICON_CURRENT_AC, STATE_CLASS_MEASUREMENT, STATE_CLASS_TOTAL_INCREASING, UNIT_HERTZ, UNIT_VOLT, UNIT_AMPERE, UNIT_WATT, UNIT_VOLT_AMPS_REACTIVE, UNIT_WATT_HOURS, ) CONF_LINE_FREQUENCY = "line_frequency" CONF_METER_CONSTANT = "meter_constant" CONF_PL_CONST = "pl_const" CONF_GAIN_PGA = "gain_pga" CONF_GAIN_METERING = "gain_metering" CONF_GAIN_VOLTAGE = "gain_voltage" CONF_GAIN_CT = "gain_ct" LINE_FREQS = { "50HZ": 50, "60HZ": 60, } PGA_GAINS = { "1X": 0x4, "4X": 0x0, "8X": 0x1, "16X": 0x2, "24X": 0x3, } atm90e26_ns = cg.esphome_ns.namespace("atm90e26") ATM90E26Component = atm90e26_ns.class_( "ATM90E26Component", cg.PollingComponent, spi.SPIDevice ) CONFIG_SCHEMA = ( cv.Schema( { cv.GenerateID(): cv.declare_id(ATM90E26Component), cv.Optional(CONF_VOLTAGE): sensor.sensor_schema( unit_of_measurement=UNIT_VOLT, accuracy_decimals=2, device_class=DEVICE_CLASS_VOLTAGE, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_CURRENT): sensor.sensor_schema( unit_of_measurement=UNIT_AMPERE, accuracy_decimals=2, device_class=DEVICE_CLASS_CURRENT, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_POWER): sensor.sensor_schema( unit_of_measurement=UNIT_WATT, accuracy_decimals=2, device_class=DEVICE_CLASS_POWER, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_REACTIVE_POWER): sensor.sensor_schema( unit_of_measurement=UNIT_VOLT_AMPS_REACTIVE, icon=ICON_LIGHTBULB, accuracy_decimals=2, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_POWER_FACTOR): sensor.sensor_schema( accuracy_decimals=2, device_class=DEVICE_CLASS_POWER_FACTOR, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_FORWARD_ACTIVE_ENERGY): sensor.sensor_schema( unit_of_measurement=UNIT_WATT_HOURS, accuracy_decimals=2, device_class=DEVICE_CLASS_ENERGY, state_class=STATE_CLASS_TOTAL_INCREASING, ), cv.Optional(CONF_REVERSE_ACTIVE_ENERGY): sensor.sensor_schema( unit_of_measurement=UNIT_WATT_HOURS, accuracy_decimals=2, device_class=DEVICE_CLASS_ENERGY, state_class=STATE_CLASS_TOTAL_INCREASING, ), cv.Optional(CONF_FREQUENCY): sensor.sensor_schema( unit_of_measurement=UNIT_HERTZ, icon=ICON_CURRENT_AC, accuracy_decimals=1, state_class=STATE_CLASS_MEASUREMENT, ), cv.Required(CONF_LINE_FREQUENCY): cv.enum(LINE_FREQS, upper=True), cv.Required(CONF_METER_CONSTANT): cv.positive_float, cv.Optional(CONF_PL_CONST, default=1429876): cv.uint32_t, cv.Optional(CONF_GAIN_METERING, default=7481): cv.uint16_t, cv.Optional(CONF_GAIN_VOLTAGE, default=26400): cv.int_range( min=0, max=32767 ), cv.Optional(CONF_GAIN_CT, default=31251): cv.uint16_t, cv.Optional(CONF_GAIN_PGA, default="1X"): cv.enum(PGA_GAINS, upper=True), } ) .extend(cv.polling_component_schema("60s")) .extend(spi.spi_device_schema()) ) async def to_code(config): var = cg.new_Pvariable(config[CONF_ID]) await cg.register_component(var, config) await spi.register_spi_device(var, config) if voltage_config := config.get(CONF_VOLTAGE): sens = await sensor.new_sensor(voltage_config) cg.add(var.set_voltage_sensor(sens)) if current_config := config.get(CONF_CURRENT): sens = await sensor.new_sensor(current_config) cg.add(var.set_current_sensor(sens)) if power_config := config.get(CONF_POWER): sens = await sensor.new_sensor(power_config) cg.add(var.set_power_sensor(sens)) if reactive_power_config := config.get(CONF_REACTIVE_POWER): sens = await sensor.new_sensor(reactive_power_config) cg.add(var.set_reactive_power_sensor(sens)) if power_factor_config := config.get(CONF_POWER_FACTOR): sens = await sensor.new_sensor(power_factor_config) cg.add(var.set_power_factor_sensor(sens)) if forward_active_energy_config := config.get(CONF_FORWARD_ACTIVE_ENERGY): sens = await sensor.new_sensor(forward_active_energy_config) cg.add(var.set_forward_active_energy_sensor(sens)) if reverse_active_energy_config := config.get(CONF_REVERSE_ACTIVE_ENERGY): sens = await sensor.new_sensor(reverse_active_energy_config) cg.add(var.set_reverse_active_energy_sensor(sens)) if frequency_config := config.get(CONF_FREQUENCY): sens = await sensor.new_sensor(frequency_config) cg.add(var.set_freq_sensor(sens)) cg.add(var.set_line_freq(config[CONF_LINE_FREQUENCY])) cg.add(var.set_meter_constant(config[CONF_METER_CONSTANT])) cg.add(var.set_pl_const(config[CONF_PL_CONST])) cg.add(var.set_gain_metering(config[CONF_GAIN_METERING])) cg.add(var.set_gain_voltage(config[CONF_GAIN_VOLTAGE])) cg.add(var.set_gain_ct(config[CONF_GAIN_CT])) cg.add(var.set_gain_pga(config[CONF_GAIN_PGA]))