1
0
mirror of https://github.com/USA-RedDragon/badnest.git synced 2024-10-05 18:40:49 +01:00

Round humidity changes to nearest 5% instead of down

This commit is contained in:
Chris Marcellino 2020-01-19 15:09:22 -06:00
parent 5b3c70e0ec
commit f1ebd8a2f7

View File

@ -279,7 +279,7 @@ class NestClimate(ClimateDevice):
def set_humidity(self, humidity):
"""Set new target humidity."""
humidity -= humidity % ROUND_TARGET_HUMIDITY_TO_NEAREST
humidity = int(round(float(humidity) / ROUND_TARGET_HUMIDITY_TO_NEAREST) * ROUND_TARGET_HUMIDITY_TO_NEAREST)
if humidity < NEST_HUMIDITY_MIN:
humidity = NEST_HUMIDITY_MIN
if humidity > NEST_HUMIDITY_MAX: