.. _daq_setup:
|
|
|
|
DAQ Server Guide
|
|
================
|
|
|
|
NI-DAQ, or just "DAQ", is the Data Acquisition device developed by National
|
|
Instruments:
|
|
|
|
http://www.ni.com/data-acquisition/
|
|
|
|
WA uses the DAQ to collect power measurements during workload execution. A
|
|
client/server solution for this is distributed as part of WA, though it is
|
|
distinct from WA and may be used separately (by invoking the client APIs from a
|
|
Python script, or used directly from the command line).
|
|
|
|
This solution is dependent on the NI-DAQmx driver for the DAQ device. At the
|
|
time of writing, only Windows versions of the driver are supported (there is an
|
|
old Linux version that works on some versions of RHEL and Centos, but it is
|
|
unsupported and won't work with recent Linux kernels). Because of this, the
|
|
server part of the solution will need to be run on a Windows machine (though it
|
|
should also work on Linux, if the driver becomes available).
|
|
|
|
|
|
.. _daq_wiring:
|
|
|
|
DAQ Device Wiring
|
|
-----------------
|
|
|
|
The server expects the device to be wired in a specific way in order to be able
|
|
to collect power measurements. Two consecutive Analogue Input (AI) channels on
|
|
the DAQ are used to form a logical "port" (starting with AI/0 and AI/1 for port
|
|
0). Of these, the lower/even channel (e.g. AI/0) is used to measure the voltage
|
|
on the rail we're interested in; the higher/odd channel (e.g. AI/1) is used to
|
|
measure the voltage drop across a known very small resistor on the same rail,
|
|
which is then used to calculate current. The logical wiring diagram looks like
|
|
this::
|
|
|
|
Port N
|
|
======
|
|
|
|
|
| AI/(N*2)+ <--- Vr -------------------------|
|
|
| |
|
|
| AI/(N*2)- <--- GND -------------------// |
|
|
| |
|
|
| AI/(N*2+1)+ <--- V ------------|-------V |
|
|
| r | |
|
|
| AI/(N*2+1)- <--- Vr --/\/\/\----| |
|
|
| | |
|
|
| | |
|
|
| |------------------------------|
|
|
======
|
|
|
|
Where:
|
|
V: Voltage going into the resistor
|
|
Vr: Voltage between resistor and the SOC
|
|
GND: Ground
|
|
r: The resistor across the rail with a known
|
|
small value.
|
|
|
|
|
|
The physical wiring will depend on the specific DAQ device, as channel layout
|
|
varies between models.
|
|
|
|
.. note:: Current solution supports variable number of ports, however it
|
|
assumes that the ports are sequential and start at zero. E.g. if you
|
|
want to measure power on three rails, you will need to wire ports 0-2
|
|
(AI/0 to AI/5 channels on the DAQ) to do it. It is not currently
|
|
possible to use any other configuration (e.g. ports 1, 2 and 5).
|
|
|
|
|
|
As an example, the following illustration shows the wiring of PORT0 (using AI/0
|
|
and AI/1 channels) on a DAQ USB-6210
|
|
|
|
.. image:: daq-wiring.png
|
|
:scale: 70 %
|
|
|
|
Setting up NI-DAQmx driver on a Windows Machine
|
|
-----------------------------------------------
|
|
|
|
- The NI-DAQmx driver is pretty big in size, 1.5 GB. The driver name is
|
|
'NI-DAQmx' and its version '9.7.0f0' which you can obtain it from National
|
|
Instruments website by downloading NI Measurement & Automation Explorer (Ni
|
|
MAX) from: http://joule.ni.com/nidu/cds/view/p/id/3811/lang/en
|
|
|
|
.. note:: During the installation process, you might be prompted to install
|
|
.NET framework 4.
|
|
|
|
- The installation process is quite long, 7-15 minutes.
|
|
- Once installed, open NI MAX, which should be in your desktop, if not type its
|
|
name in the start->search.
|
|
- Connect the NI-DAQ device to your machine. You should see it appear under
|
|
'Devices and Interfaces'. If not, press 'F5' to refresh the list.
|
|
- Complete the device wiring as described in the :ref:`daq_wiring` section.
|
|
- Quit NI MAX.
|
|
|
|
|
|
Setting up DAQ server
|
|
---------------------
|
|
|
|
The DAQ power measurement solution is implemented in daqpower Python library,
|
|
the package for which can be found in WA's install location under
|
|
``wlauto/external/daq_server/daqpower-1.0.0.tar.gz`` (the version number in your
|
|
installation may be different).
|
|
|
|
- Install NI-DAQmx driver, as described in the previous section.
|
|
- Install Python 2.7.
|
|
- Download and install ``pip``, ``numpy`` and ``twisted`` Python packages.
|
|
These packages have C extensions, an so you will need a native compiler set
|
|
up if you want to install them from PyPI. As an easier alternative, you can
|
|
find pre-built Windows installers for these packages here_ (the versions are
|
|
likely to be older than what's on PyPI though).
|
|
- Install the daqpower package using pip::
|
|
|
|
pip install C:\Python27\Lib\site-packages\wlauto\external\daq_server\daqpower-1.0.0.tar.gz
|
|
|
|
This should automatically download and install ``PyDAQmx`` package as well
|
|
(the Python bindings for the NI-DAQmx driver).
|
|
|
|
.. _here: http://www.lfd.uci.edu/~gohlke/pythonlibs/
|
|
|
|
|
|
Running DAQ server
|
|
------------------
|
|
|
|
Once you have installed the ``daqpower`` package and the required dependencies as
|
|
described above, you can start the server by executing ``run-daq-server`` from the
|
|
command line. The server will start listening on the default port, 45677.
|
|
|
|
.. note:: There is a chance that pip will not add ``run-daq-server`` into your
|
|
path. In that case, you can run daq server as such:
|
|
``python C:\path to python\Scripts\run-daq-server``
|
|
|
|
You can optionally specify flags to control the behaviour or the server::
|
|
|
|
usage: run-daq-server [-h] [-d DIR] [-p PORT] [--debug] [--verbose]
|
|
|
|
optional arguments:
|
|
-h, --help show this help message and exit
|
|
-d DIR, --directory DIR
|
|
Working directory
|
|
-p PORT, --port PORT port the server will listen on.
|
|
--debug Run in debug mode (no DAQ connected).
|
|
--verbose Produce verobose output.
|
|
|
|
.. note:: The server will use a working directory (by default, the directory
|
|
the run-daq-server command was executed in, or the location specified
|
|
with -d flag) to store power traces before they are collected by the
|
|
client. This directory must be read/write-able by the user running
|
|
the server.
|
|
|
|
|
|
Collecting Power with WA
|
|
------------------------
|
|
|
|
.. note:: You do *not* need to install the ``daqpower`` package on the machine
|
|
running WA, as it is already included in the WA install structure.
|
|
However, you do need to make sure that ``twisted`` package is
|
|
installed.
|
|
|
|
You can enable ``daq`` instrument your agenda/config.py in order to get WA to
|
|
collect power measurements. At minimum, you will also need to specify the
|
|
resistor values for each port in your configuration, e.g.::
|
|
|
|
resistor_values = [0.005, 0.005] # in Ohms
|
|
|
|
This also specifies the number of logical ports (measurement sites) you want to
|
|
use, and, implicitly, the port numbers (ports 0 to N-1 will be used).
|
|
|
|
.. note:: "ports" here refers to the logical ports wired on the DAQ (see :ref:`daq_wiring`,
|
|
not to be confused with the TCP port the server is listening on.
|
|
|
|
Unless you're running the DAQ server and WA on the same machine (unlikely
|
|
considering that WA is officially supported only on Linux and recent NI-DAQmx
|
|
drivers are only available on Windows), you will also need to specify the IP
|
|
address of the server::
|
|
|
|
daq_server = 127.0.0.1
|
|
|
|
There are a number of other settings that can optionally be specified in the
|
|
configuration (e.g. the labels to be used for DAQ ports). Please refer to the
|
|
:class:`wlauto.instrumentation.daq.Daq` documentation for details.
|
|
|
|
|
|
Collecting Power from the Command Line
|
|
--------------------------------------
|
|
|
|
``daqpower`` package also comes with a client that may be used from the command
|
|
line. Unlike when collecting power with WA, you *will* need to install the
|
|
``daqpower`` package. Once installed, you will be able to interract with a
|
|
running DAQ server by invoking ``send-daq-command``. The invocation syntax is ::
|
|
|
|
send-daq-command --host HOST [--port PORT] COMMAND [OPTIONS]
|
|
|
|
Options are command-specific. COMMAND may be one of the following (and they
|
|
should generally be inoked in that order):
|
|
|
|
:configure: Set up a new session, specifying the configuration values to
|
|
be used. If there is already a configured session, it will
|
|
be terminated. OPTIONS for this this command are the DAQ
|
|
configuration parameters listed in the DAQ instrument
|
|
documentation with all ``_`` replaced by ``-`` and prefixed
|
|
with ``--``, e.g. ``--resistor-values``.
|
|
:start: Start collecting power measurments.
|
|
:stop: Stop collecting power measurments.
|
|
:get_data: Pull files containg power measurements from the server.
|
|
There is one option for this command:
|
|
``--output-directory`` which specifies where the files will
|
|
be pulled to; if this is not specified, the will be in the
|
|
current directory.
|
|
:close: Close the currently configured server session. This will get rid
|
|
of the data files and configuration on the server, so it would
|
|
no longer be possible to use "start" or "get_data" commands
|
|
before a new session is configured.
|
|
|
|
A typical command line session would go like this:
|
|
|
|
.. code-block:: bash
|
|
|
|
send-daq-command --host 127.0.0.1 configure --resistor-values 0.005 0.005
|
|
# set up and kick off the use case you want to measure
|
|
send-daq-command --host 127.0.0.1 start
|
|
# wait for the use case to complete
|
|
send-daq-command --host 127.0.0.1 stop
|
|
send-daq-command --host 127.0.0.1 get_data
|
|
# files called PORT_0.csv and PORT_1.csv will appear in the current directory
|
|
# containing measurements collected during use case execution
|
|
send-daq-command --host 127.0.0.1 close
|
|
# the session is terminated and the csv files on the server have been
|
|
# deleted. A new session may now be configured.
|
|
|
|
In addtion to these "standard workflow" commands, the following commands are
|
|
also available:
|
|
|
|
:list_devices: Returns a list of DAQ devices detected by the NI-DAQmx
|
|
driver. In case mutiple devices are connected to the
|
|
server host, you can specify the device you want to use
|
|
with ``--device-id`` option when configuring a session.
|
|
:list_ports: Returns a list of ports tha have been configured for the
|
|
current session, e.g. ``['PORT_0', 'PORT_1']``.
|
|
:list_port_files: Returns a list of data files that have been geneted
|
|
(unless something went wrong, there should be one for
|
|
each port).
|
|
|
|
|
|
Collecting Power from another Python Script
|
|
-------------------------------------------
|
|
|
|
You can invoke the above commands from a Python script using
|
|
:py:func:`daqpower.client.execute_command` function, passing in
|
|
:class:`daqpower.config.ServerConfiguration` and, in case of the configure command,
|
|
:class:`daqpower.config.DeviceConfigruation`. Please see the implementation of
|
|
the ``daq`` WA instrument for examples of how these APIs can be used.
|