1
0
mirror of https://github.com/ARM-software/workload-automation.git synced 2024-10-06 10:51:13 +01:00
Commit Graph

44 Commits

Author SHA1 Message Date
Marc Bonnici
1f8be77331 Disable pep8 errors 2020-05-13 16:43:03 +01:00
Marc Bonnici
607cff4c54 framework: Lock files which could be read/written to concurrently
Add file locking to files that could be read and written to concurrently
by separate wa processes causing race conditions.
2020-04-09 09:14:39 +01:00
Sergei Trofimov
51ffd60c06 instruments: add proc_stat
Add an instrument that monitors CPU load using data from /proc/stat
2020-02-07 14:11:31 +00:00
Marc Bonnici
90db655959 instrument/perf: Fix incorrect argument 2019-12-20 16:07:10 +00:00
Marc Bonnici
817d98ed72 wa/instruments: Refactor collectors to use Collector Inferface
Update the WA instruments which rely on the refactored devlib collectors
to reflect the new API.
2019-12-20 15:17:01 +00:00
Marc Bonnici
5906bca6b3 instruments/acme_cape: Fix missing parameter to get_instruments
The signature of `get_instruments` was missing the `keep_raw` parameter
so fix this and use it as part of the subsequent common invocation.
2019-11-18 16:09:09 +00:00
Marc Bonnici
d7c95fa844 instrument/energy_measurement: Fix typo and formatting 2019-10-03 12:48:24 +01:00
Marc Bonnici
e41aa3c967 instruments/energy_measurement: Add a keep_raw parameter
Add a `keep_raw` parameter to control whether raw files should be
deleted during teardown.
2019-10-03 11:38:29 +01:00
Marc Bonnici
3bef4fc92d instrument/energy_measurement: Invoke teardown method for backends
Forward the teardown method invocation to the instrument backend.
2019-10-03 08:39:53 +01:00
Robert Freeman
6beac11ee2 Add simpleperf type to perf instrument
* Added simpleperf type to perf instrument as it's more stable
  on Android devices.
* Added record command to instrument
* Added output processing for simpleperf
2019-09-18 12:55:59 +01:00
Marc Bonnici
12bb21045e instruments/SysfsExtractor: Add extracted directories as artifacts
Add the directories that have been extracted by the `SysfsExtractor` and
derived instruments as artifacts.
2019-07-19 16:36:11 +01:00
Marc Bonnici
31e08a6477 instruments/interrupts: Add interrupt files as artifacts
Ensure that the interrupt files pulled and diffed from the device are
added as artifacts.
2019-07-19 16:36:11 +01:00
Marc Bonnici
e3406bdb74 instruments/delay: Convert module name to identifier
- Ensure cooling module name is converted to identifier when resolving
- Fix typo
2019-04-26 08:04:45 +01:00
pablololo12
7cd7b73f58 Fixed an error emptying the reading buffer of the poller
Fixed identation

Fixed identation
2019-02-04 09:46:13 +00:00
Marc Bonnici
ce7720b26d instruments/fps: Fix Typo 2019-01-28 12:45:10 +00:00
Marc Bonnici
fce506eb02 instruments/misc: Fix typo 2018-09-21 15:06:30 +01:00
Marc Bonnici
b20b9f9cad instruments/perf: Port the perf instrument to WA3 2018-09-06 08:39:09 +01:00
Marc Bonnici
4a9b24a9a8 instruments/energy_measurments: Improve instrument description
Add note to users that all configuration for the backends should be
added through this instrument rather than directly.
2018-08-14 13:41:39 +01:00
Marc Bonnici
d007b283df instruments/trace_cmd: Fix reporting on target
If reporting on the target the extracted trace data file was not
defined, now locate the file correctly.
2018-07-24 11:34:00 +01:00
Sergei Trofimov
c410d2e1a1 I lint, therefore I am
Implement fixes for the most recent pylint version.
2018-07-09 15:59:40 +01:00
Marc Bonnici
925bc8b719 wa: pep8 fixes 2018-07-06 14:39:41 +01:00
Marc Bonnici
6afd710bd1 wa/instruments: pylint/fixes 2018-07-06 14:39:41 +01:00
Marc Bonnici
0b8501e010 wa/instruments: pep8 fixes 2018-07-06 14:39:41 +01:00
Sergei Trofimov
8878cc20d4 Update copyright headers.
- Add copyright headers to files that did not already have them
- Update the year to the last year the file was modified in files with
  existing headers.
2018-07-04 16:33:31 +01:00
Sascha Bischoff
7fb85261da instruments/serialmon: Add an instrument to monitor serial traffic
This instrument will log serial traffic to a file. The idea is to
assist with debugging development boards, as otherwise there is a
chance that crash reports, for example, are lost when the device is
reset by WA.

It logs the pre-run and post-run traffic to preamble_serial.log and
postamble_serial.log , respectively, in the top-level output
directory. Serial logs for each workload are stored in the appropriate
workload directory as serial.log.

As we are tying up the serial port, we stop the logging when the
device is reset to allow board such as the Arm Juno to be reset via
the serial connection.
2018-06-13 14:36:46 +01:00
Sergei Trofimov
b3de85455a Add support for Python 3
Add support for running under Python 3, while maintaining compatibility
with Python 2.

See http://python-future.org/compatible_idioms.html for more details
behind these changes.
2018-06-07 14:48:40 +01:00
Sergei Trofimov
aee8b10f26 doc/delay: fix warning.
Add space between a note admonition and the preceding paragraph.
2018-06-01 17:18:43 +01:00
Marc Bonnici
ba717bbcd1 instrument/delay: Remove breakpoint 2018-05-30 12:25:58 +01:00
Marc Bonnici
ceadb36880 instruments/delay: Port instrument to WA3
Port the delay instrument to WA3.
2018-05-30 12:22:46 +01:00
Sergei Trofimov
18bf314592 doc: fix missing reference to daq_setup
Since daq-server has been split out into a separate package, daq setup
is no longer part of WA documentation. This resulted in a warning when
building the docs.
2018-05-25 15:27:14 +01:00
Sergei Trofimov
2ff06af632 fw/execution: record resource hashes in metadata
As part of resolving a resource, record its MD5 hash in the output
metadata. In order to enable this, resource resolution is now done via
the context, rather than directly via the ResourceResolver (in order not
to introduce a context dependency in the Gui object, context now
emulates the resolver interface).
2018-05-25 10:21:06 +01:00
Sergei Trofimov
ec66ae2f6f instrument/trace_cmd: Log the pulling of trace
Extracting trace and pulling the trace file from the target can take a
relatively long time, as the trace file can be tens, and even hundreds,
of MB. Add an info-level log message to inform the user why WA execution
appears to have paused for a few seconds.
2018-05-14 17:05:06 +01:00
sergei Trofimov
6965c05707 instruments/energy_measurement: add missing docs
- Add missing descriptions to backends.
- Describe how to get instrument-specific parameter descriptions in the
  help for instrument_parameters param of EnergyMeasurementInstrument
2018-04-27 18:10:02 +01:00
Sascha Bischoff
3b7debe676 instruments: Add screencap
Add an instrument which wraps the devlib screencapture poller, which
allows us to capture a screenshot from the device every `period`. The
`period` is configurable based on the user requirements.

All captured screenshots are named according to the timestamp on the
device, and are placed into an output directory (screen-capture)
within the job directory.
2018-04-24 10:04:22 +01:00
Vincent Guittot
741193c441 daq: fix resistor_values and sample_rate_hz parameters list
resistor_values is an array of float and not int as the shunt resistors
are most of the time lower than 1 Ohm.
With kind=list_of_ints, all resistor values are rounded to 0. Replace it
by list_of_numbers

sample_rate_hz is an int used to get sample period and to compute energy.
Changes its type from str to int

With these 2 fixes, the daq instrument has been successfully tested with
NI DAQ6211

Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
2018-04-03 08:36:06 +01:00
Vincent Guittot
06fc361f47 aep: fix variable typo
something wrong has happened when preparing the patch to add
arm-probe AEP support

Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
2018-03-29 19:41:23 +01:00
Vincent Guittot
ec316eab03 Add arm energy probe instrument
Arm Energy Probe with arm_probe has been recently added in devlib's
instrument.
Add the arm_energy_probe in the WA list of Energy measurement instruments

Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
2018-03-28 09:29:08 +01:00
Vincent Guittot
3c1369c268 Add meta directory to get_instruments function
energy instruments might need to save platform specific configurations in
order to help to reproduce the use case. Such configuration should be saved in
__meta directory.
Add the directory path as a parameter of get_instruments() to save such
informations

Suggested-by: setrofim@gmail.com
Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
2018-03-28 09:29:08 +01:00
Marc Bonnici
c1cc18df2f instruments/DAQBackend: Add global aliases 2018-03-20 08:24:58 +00:00
Sergei Trofimov
12a33c8aeb framework: move instruments -> instrument
Use the singular to be consistent with other modules in wa.framework.
2018-02-22 08:41:04 +00:00
Marc Bonnici
ed77855949 instruments/trace-cmd: Only insert trace markers if enabled
Check to see if the instrument is enabled before adding start and stop
trace markers.
2018-02-01 14:26:08 +00:00
Marc Bonnici
e5ed64d8d5 trace_cmd: Rename trace-cmd to trace_cmd
Both the instrument and utility functions were called `trace-cmd.py`.
`"-"`'s are not valid python identifiers therefore when trying to import
the `trace-cmd` module this causes an error.
2018-01-25 16:28:51 +00:00
Sergei Trofimov
902c3c6ace instruments/poller: add ftrace marker support
- Add an option to the poller binary insert a marker into ftrace that
  aligns with the first output entry. The option is exposed as an
  instrument parameter.
- If this parameter is set, the resulting .csv will be post-processed to
  update the timestamps to align with trace-cmd output.
- Change poller artifact names to use - instead of _ to be consistent
  with trace-cmd artifact naming.
2018-01-25 10:50:02 +00:00
Marc Bonnici
446a1cfbb0 wa: Rename Instrumentation to Instruments
To be maintain a consistent naming scheme, rename all instances of
`Instrumentation` to `Instruments`
2018-01-15 10:24:03 +00:00