- Add missing descriptions to backends.
- Describe how to get instrument-specific parameter descriptions in the
help for instrument_parameters param of EnergyMeasurementInstrument
resistor_values is an array of float and not int as the shunt resistors
are most of the time lower than 1 Ohm.
With kind=list_of_ints, all resistor values are rounded to 0. Replace it
by list_of_numbers
sample_rate_hz is an int used to get sample period and to compute energy.
Changes its type from str to int
With these 2 fixes, the daq instrument has been successfully tested with
NI DAQ6211
Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
Arm Energy Probe with arm_probe has been recently added in devlib's
instrument.
Add the arm_energy_probe in the WA list of Energy measurement instruments
Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
energy instruments might need to save platform specific configurations in
order to help to reproduce the use case. Such configuration should be saved in
__meta directory.
Add the directory path as a parameter of get_instruments() to save such
informations
Suggested-by: setrofim@gmail.com
Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>