adding device_entry parameter to energy probe instrument
This commit is contained in:
parent
e87e4c582c
commit
cd6babeab1
@ -53,6 +53,8 @@ class EnergyProbe(Instrument):
|
||||
description="""The value of shunt resistors. This is a mandatory parameter."""),
|
||||
Parameter('labels', kind=list, default=[],
|
||||
description="""Meaningful labels for each of the monitored rails."""),
|
||||
Parameter('device_entry', kind=str, default='/dev/ttyACM0',
|
||||
description="""Path to /dev entry for the energy probe (it should be /dev/ttyACMx)"""),
|
||||
]
|
||||
|
||||
MAX_CHANNELS = 3
|
||||
@ -84,7 +86,7 @@ class EnergyProbe(Instrument):
|
||||
rstring = ""
|
||||
for i, rval in enumerate(self.resistor_values):
|
||||
rstring += '-r {}:{} '.format(i, rval)
|
||||
self.command = 'caiman -l {} {}'.format(rstring, self.output_directory)
|
||||
self.command = 'caiman -d {} -l {} {}'.format(self.device_entry, rstring, self.output_directory)
|
||||