mirror of
				https://github.com/ARM-software/workload-automation.git
				synced 2025-10-31 07:04:17 +00:00 
			
		
		
		
	Initial commit of open source Workload Automation.
This commit is contained in:
		
							
								
								
									
										77
									
								
								wlauto/instrumentation/juno_energy/__init__.py
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										77
									
								
								wlauto/instrumentation/juno_energy/__init__.py
									
									
									
									
									
										Normal file
									
								
							| @@ -0,0 +1,77 @@ | ||||
| #    Copyright 2014-2015 ARM Limited | ||||
| # | ||||
| # Licensed under the Apache License, Version 2.0 (the "License"); | ||||
| # you may not use this file except in compliance with the License. | ||||
| # You may obtain a copy of the License at | ||||
| # | ||||
| #     http://www.apache.org/licenses/LICENSE-2.0 | ||||
| # | ||||
| # Unless required by applicable law or agreed to in writing, software | ||||
| # distributed under the License is distributed on an "AS IS" BASIS, | ||||
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. | ||||
| # See the License for the specific language governing permissions and | ||||
| # limitations under the License. | ||||
| # | ||||
|  | ||||
|  | ||||
| # pylint: disable=W0613,W0201 | ||||
| import os | ||||
| import csv | ||||
| import time | ||||
| import threading | ||||
| import logging | ||||
| from operator import itemgetter | ||||
|  | ||||
| from wlauto import Instrument, File, Parameter | ||||
| from wlauto.exceptions import InstrumentError | ||||
|  | ||||
|  | ||||
| class JunoEnergy(Instrument): | ||||
|  | ||||
|     name = 'juno_energy' | ||||
|     description = """ | ||||
|     Collects internal energy meter measurements from Juno development board. | ||||
|  | ||||
|     This instrument was created because (at the time of creation) Juno's energy | ||||
|     meter measurements aren't exposed through HWMON or similar standardized mechanism, | ||||
|     necessitating  a dedicated instrument to access them. | ||||
|  | ||||
|     This instrument, and the ``readenergy`` executable it relies on are very much tied | ||||
|     to the Juno platform and are not expected to work on other boards. | ||||
|  | ||||
|     """ | ||||
|  | ||||
|     parameters = [ | ||||
|         Parameter('period', kind=float, default=0.1, | ||||
|                   description='Specifies the time, in Seconds, between polling energy counters.'), | ||||
|     ] | ||||
|  | ||||
|     def on_run_init(self, context): | ||||
|         local_file = context.resolver.get(File(self, 'readenergy')) | ||||
|         self.device.killall('readenergy', as_root=True) | ||||
|         self.readenergy = self.device.install(local_file) | ||||
|  | ||||
|     def setup(self, context): | ||||
|         self.host_output_file = os.path.join(context.output_directory, 'energy.csv') | ||||
|         self.device_output_file = self.device.path.join(self.device.working_directory, 'energy.csv') | ||||
|         self.command = '{} -o {}'.format(self.readenergy, self.device_output_file) | ||||
|         self.device.killall('readenergy', as_root=True) | ||||
|  | ||||
|     def start(self, context): | ||||
|         self.device.kick_off(self.command) | ||||
|  | ||||
|     def stop(self, context): | ||||
|         self.device.killall('readenergy', signal='TERM', as_root=True) | ||||
|  | ||||
|     def update_result(self, context): | ||||
|         self.device.pull_file(self.device_output_file, self.host_output_file) | ||||
|         context.add_artifact('junoenergy', self.host_output_file, 'data') | ||||
|  | ||||
|     def teardown(self, conetext): | ||||
|         self.device.delete_file(self.device_output_file) | ||||
|  | ||||
|     def validate(self): | ||||
|         if self.device.name.lower() != 'juno': | ||||
|             message = 'juno_energy instrument is only supported on juno devices; found {}' | ||||
|             raise InstrumentError(message.format(self.device.name)) | ||||
|  | ||||
							
								
								
									
										
											BIN
										
									
								
								wlauto/instrumentation/juno_energy/readenergy
									
									
									
									
									
										Executable file
									
								
							
							
						
						
									
										
											BIN
										
									
								
								wlauto/instrumentation/juno_energy/readenergy
									
									
									
									
									
										Executable file
									
								
							
										
											Binary file not shown.
										
									
								
							
		Reference in New Issue
	
	Block a user