mirror of
				https://github.com/ARM-software/workload-automation.git
				synced 2025-10-31 15:12:25 +00:00 
			
		
		
		
	daq: fix resistor_values and sample_rate_hz parameters list
resistor_values is an array of float and not int as the shunt resistors are most of the time lower than 1 Ohm. With kind=list_of_ints, all resistor values are rounded to 0. Replace it by list_of_numbers sample_rate_hz is an int used to get sample period and to compute energy. Changes its type from str to int With these 2 fixes, the daq instrument has been successfully tested with NI DAQ6211 Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
This commit is contained in:
		
				
					committed by
					
						 setrofim
						setrofim
					
				
			
			
				
	
			
			
			
						parent
						
							117f0f9fc4
						
					
				
				
					commit
					741193c441
				
			| @@ -20,6 +20,8 @@ from collections import defaultdict | |||||||
| import os | import os | ||||||
| import shutil | import shutil | ||||||
|  |  | ||||||
|  | from wa.utils.types import list_of_numbers | ||||||
|  |  | ||||||
| from devlib import DerivedEnergyMeasurements | from devlib import DerivedEnergyMeasurements | ||||||
| from devlib.instrument import CONTINUOUS | from devlib.instrument import CONTINUOUS | ||||||
| from devlib.instrument.energy_probe import EnergyProbeInstrument | from devlib.instrument.energy_probe import EnergyProbeInstrument | ||||||
| @@ -65,7 +67,7 @@ class DAQBackend(EnergyInstrumentBackend): | |||||||
|     name = 'daq' |     name = 'daq' | ||||||
|  |  | ||||||
|     parameters = [ |     parameters = [ | ||||||
|         Parameter('resistor_values', kind=list_of_ints, |         Parameter('resistor_values', kind=list_of_numbers, | ||||||
|                   global_alias='daq_resistor_values', |                   global_alias='daq_resistor_values', | ||||||
|                   description=""" |                   description=""" | ||||||
|                   The values of resistors (in Ohms) across which the voltages |                   The values of resistors (in Ohms) across which the voltages | ||||||
| @@ -106,7 +108,7 @@ class DAQBackend(EnergyInstrumentBackend): | |||||||
|                   Specifies the voltage range for the resistor voltage channel |                   Specifies the voltage range for the resistor voltage channel | ||||||
|                   on the DAQ (please refer to :ref:`daq_setup` for details). |                   on the DAQ (please refer to :ref:`daq_setup` for details). | ||||||
|                   """), |                   """), | ||||||
|         Parameter('sample_rate_hz', kind=str, default=10000, |         Parameter('sample_rate_hz', kind=int, default=10000, | ||||||
|                   global_alias='daq_sampling_rate', |                   global_alias='daq_sampling_rate', | ||||||
|                   description=""" |                   description=""" | ||||||
|                   Specify the sample rate in Hz. |                   Specify the sample rate in Hz. | ||||||
|   | |||||||
		Reference in New Issue
	