1
0
mirror of https://github.com/ARM-software/workload-automation.git synced 2025-02-21 20:38:57 +00:00

EnergyMeaseurement: Adds support for acme_cape

This commit is contained in:
Marc Bonnici 2017-07-26 10:06:54 +01:00
parent b98b74f0be
commit 5f919445d9

View File

@ -22,6 +22,8 @@ from collections import defaultdict
from devlib.instrument import CONTINUOUS from devlib.instrument import CONTINUOUS
from devlib.instrument.energy_probe import EnergyProbeInstrument from devlib.instrument.energy_probe import EnergyProbeInstrument
from devlib.instrument.daq import DaqInstrument from devlib.instrument.daq import DaqInstrument
from devlib.instrument.acmecape import AcmeCapeInstrument
from devlib.utils.misc import which
from wa import Instrument, Parameter from wa import Instrument, Parameter
from wa.framework import pluginloader from wa.framework import pluginloader
@ -140,6 +142,31 @@ class EnergyProbeBackend(EnergyInstrumentBackend):
msg = 'Number of Energy Probe port labels does not match the number of resistor values.' msg = 'Number of Energy Probe port labels does not match the number of resistor values.'
raise ConfigError(msg) raise ConfigError(msg)
class AcmeCapeBackend(EnergyInstrumentBackend):
name = 'acme_cape'
parameters = [
Parameter('iio-capture', default=which('iio-capture'),
description="""
Path to the iio-capture binary will be taken from the
environment, if not specfied.
"""),
Parameter('host', default='baylibre-acme.local',
description="""
Host name (or IP address) of the ACME cape board.
"""),
Parameter('iio-device', default='iio:device0',
description="""
"""),
Parameter('buffer-size', kind=int, default=256,
description="""
Size of the capture buffer (in KB).
"""),
]
instrument = AcmeCapeInstrument
class EnergyMeasurement(Instrument): class EnergyMeasurement(Instrument):
@ -152,7 +179,7 @@ class EnergyMeasurement(Instrument):
parameters = [ parameters = [
Parameter('instrument', kind=str, mandatory=True, Parameter('instrument', kind=str, mandatory=True,
allowed_values=['daq', 'energy_probe'], allowed_values=['daq', 'energy_probe', 'acme_cape'],
description=""" description="""
Specify the energy instrumentation to be enabled. Specify the energy instrumentation to be enabled.
"""), """),