mirror of
				https://github.com/ARM-software/workload-automation.git
				synced 2025-10-31 15:12:25 +00:00 
			
		
		
		
	Merge pull request #469 from marcbonnici/energy_measurement
Energy measurement
This commit is contained in:
		| @@ -17,11 +17,13 @@ | ||||
| # pylint: disable=W0613,E1101 | ||||
| from __future__ import division | ||||
| import os | ||||
| from collections import defaultdict | ||||
|  | ||||
| from devlib.instrument import CONTINUOUS | ||||
| from devlib.instrument.energy_probe import EnergyProbeInstrument | ||||
| from devlib.instrument.daq import DaqInstrument | ||||
| from devlib.instrument.acmecape import AcmeCapeInstrument | ||||
| from devlib.utils.misc import which | ||||
| from devlib.derived.derived_measurements import DerivedEnergyMeasurements | ||||
|  | ||||
| from wa import Instrument, Parameter | ||||
| from wa.framework import pluginloader | ||||
| @@ -140,6 +142,31 @@ class EnergyProbeBackend(EnergyInstrumentBackend): | ||||
|                 msg = 'Number of Energy Probe port labels does not match the number of resistor values.' | ||||
|                 raise ConfigError(msg) | ||||
|  | ||||
| class AcmeCapeBackend(EnergyInstrumentBackend): | ||||
|  | ||||
|     name = 'acme_cape' | ||||
|  | ||||
|     parameters = [ | ||||
|         Parameter('iio-capture', default=which('iio-capture'), | ||||
|                   description=""" | ||||
|                   Path to the iio-capture binary will be taken from the | ||||
|                   environment, if not specfied. | ||||
|                   """), | ||||
|         Parameter('host', default='baylibre-acme.local', | ||||
|                   description=""" | ||||
|                   Host name (or IP address) of the ACME cape board. | ||||
|                   """), | ||||
|         Parameter('iio-device', default='iio:device0', | ||||
|                   description=""" | ||||
|                   """), | ||||
|         Parameter('buffer-size', kind=int, default=256, | ||||
|                   description=""" | ||||
|                   Size of the capture buffer (in KB). | ||||
|                   """), | ||||
|     ] | ||||
|  | ||||
|     instrument = AcmeCapeInstrument | ||||
|  | ||||
|  | ||||
| class EnergyMeasurement(Instrument): | ||||
|  | ||||
| @@ -152,7 +179,7 @@ class EnergyMeasurement(Instrument): | ||||
|  | ||||
|     parameters = [ | ||||
|         Parameter('instrument', kind=str, mandatory=True, | ||||
|                   allowed_values=['daq', 'energy_probe'], | ||||
|                   allowed_values=['daq', 'energy_probe', 'acme_cape'], | ||||
|                   description=""" | ||||
|                   Specify the energy instrumentation to be enabled. | ||||
|                   """), | ||||
| @@ -161,19 +188,19 @@ class EnergyMeasurement(Instrument): | ||||
|                    Specify the parameters used to initialize the desired | ||||
|                    instrumentation. | ||||
|                    """), | ||||
|         Parameter('sites', kind=list_or_string, default=[], | ||||
|         Parameter('sites', kind=list_or_string, | ||||
|                   description=""" | ||||
|                   Specify which sites measurements should be collected | ||||
|                   from, if not specified the measurements will be | ||||
|                   collected for all available sites. | ||||
|                   """), | ||||
|         Parameter('kinds', kind=list_or_string, default=[], | ||||
|         Parameter('kinds', kind=list_or_string, | ||||
|                   description=""" | ||||
|                   Specify the kinds of measurements should be collected, | ||||
|                   if not specified measurements will be | ||||
|                   collected for all available kinds. | ||||
|                   """), | ||||
|         Parameter('channels', kind=list_or_string, default=[], | ||||
|         Parameter('channels', kind=list_or_string, | ||||
|                   description=""" | ||||
|                   Specify the channels to be collected, | ||||
|                   if not specified the measurements will be | ||||
| @@ -204,7 +231,7 @@ class EnergyMeasurement(Instrument): | ||||
|     def initialize(self, context): | ||||
|         self.instrumentation = self.backend.instrument(self.target, **self.params) | ||||
|  | ||||
|         for channel in self.channels: | ||||
|         for channel in self.channels or []: | ||||
|             if not self.instrumentation.get_channels(channel): | ||||
|                 raise ConfigError('No channels found for "{}"'.format(channel)) | ||||
|  | ||||
| @@ -226,24 +253,7 @@ class EnergyMeasurement(Instrument): | ||||
|         self.extract_metrics(context) | ||||
|  | ||||
|     def extract_metrics(self, context): | ||||
|         measurements = self.measurement_csv.itermeasurements() | ||||
|         energy_results = defaultdict(dict) | ||||
|         power_results = defaultdict(int) | ||||
|  | ||||
|         for count, row in enumerate(measurements): | ||||
|             for entry in row: | ||||
|                 channel = entry.channel | ||||
|                 if channel.kind == 'energy': | ||||
|                     if count == 0: | ||||
|                         energy_results[channel.site]['start'] = entry.value | ||||
|                     else: | ||||
|                         energy_results[channel.site]['end'] = entry.value | ||||
|                 elif channel.kind == 'power': | ||||
|                     power_results[channel.site] += entry.value | ||||
|  | ||||
|         for site in energy_results: | ||||
|             total_energy = energy_results[site]['end'] - energy_results[site]['start'] | ||||
|             context.add_metric('{}_energy'.format(site), total_energy, 'joules') | ||||
|         for site in power_results: | ||||
|             power = power_results[site] / count + 1  #pylint: disable=undefined-loop-variable | ||||
|             context.add_metric('{}_power'.format(site), power, 'watts') | ||||
|         derived_measurements = DerivedEnergyMeasurements.process(self.measurement_csv) | ||||
|         for meas in derived_measurements: | ||||
|             name = '{}_{}'.format(meas.channel.site, meas.channel.name) | ||||
|             context.add_metric(name, meas.value, meas.units) | ||||
|   | ||||
		Reference in New Issue
	