1
0
mirror of https://github.com/esphome/esphome.git synced 2025-02-21 04:18:16 +00:00
David K. f2e99fa319
[bme68x_bsec2_i2c] BME68X Temperature+Pressure+Humidity+Gas Sensor via BSEC2 (#4585)
* Added initial bme68x component

* Initialize all child sensors to nullptr

This was added to all other sensors in #3808

* Update BSEC2 and BME68x Libraries

Current versions from Bosch Sensortec

* Add myself to codeowners for bme68x_bsec

* Move constants to const.py, according to ci-custom checks

Move constants to const.py, according to ci-custom checks

* Update library dependencies

We'll stick with 1.4.2200 for now. 1.4.2200 is not on platform.io registry, use tag instead.

Update to 1.5.2400 needs some work due to multi instance support.

* Update BSEC2 to 1.6.2400

* Add consts to bme680x_bsec

Enable inclusion with external_components

* Update device class for pressure

* Update to use multisensor API

* Tidy up some constants

* Add tests

* Remove scd30 changes

* Import CONF_SAMPLE_RATE

* Pull BSEC config blob from repo based on config

* Rename component to `bme68x_bsec_i2c`

* Fix tests + codeowners

* Cleanup for review

* Rename using `bsec2`

* Apply suggestions from code review

Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>

* Download file during validation stage, instead

* Make `dump_config()` only dump stuff

* Compile safely without sensor and text sensor headers

* Use `intf_ptr`

* Save state if measuring static IAQ, too

* Update CODEOWNERS

* Simplify esphome/components/bme68x_bsec2_i2c/__init__.py

Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>

* Remove extraneous colon & imports

* Track & save the maximum accuracy value

* Polish up accuracy sensor handling

* Log static sensor, update `defines.h`

* Walruses make it better

* Add some logging of setup failures

* Update esphome/components/bme68x_bsec2_i2c/bme68x_bsec2_i2c.cpp

Co-authored-by: Trevor North <trevor@freedisc.co.uk>

* Break out some things

* Update CODEOWNERS

* Update CODEOWNERS take 2

* Use `add_extra` in base schema

* Another walrus in the sensor

Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>

---------

Co-authored-by: Keith Burzinski <kbx81x@gmail.com>
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
Co-authored-by: Trevor North <trevor@freedisc.co.uk>
2024-08-11 23:14:58 -05:00

131 lines
4.2 KiB
Python

import esphome.codegen as cg
from esphome.components import sensor
import esphome.config_validation as cv
from esphome.const import (
CONF_GAS_RESISTANCE,
CONF_HUMIDITY,
CONF_IAQ_ACCURACY,
CONF_PRESSURE,
CONF_SAMPLE_RATE,
CONF_TEMPERATURE,
DEVICE_CLASS_ATMOSPHERIC_PRESSURE,
DEVICE_CLASS_HUMIDITY,
DEVICE_CLASS_TEMPERATURE,
ICON_GAS_CYLINDER,
ICON_GAUGE,
ICON_THERMOMETER,
ICON_WATER_PERCENT,
STATE_CLASS_MEASUREMENT,
UNIT_CELSIUS,
UNIT_HECTOPASCAL,
UNIT_OHM,
UNIT_PARTS_PER_MILLION,
UNIT_PERCENT,
)
from . import CONF_BME68X_BSEC2_ID, SAMPLE_RATE_OPTIONS, BME68xBSEC2Component
DEPENDENCIES = ["bme68x_bsec2"]
CONF_BREATH_VOC_EQUIVALENT = "breath_voc_equivalent"
CONF_CO2_EQUIVALENT = "co2_equivalent"
CONF_IAQ = "iaq"
CONF_IAQ_STATIC = "iaq_static"
ICON_ACCURACY = "mdi:checkbox-marked-circle-outline"
ICON_TEST_TUBE = "mdi:test-tube"
UNIT_IAQ = "IAQ"
TYPES = [
CONF_TEMPERATURE,
CONF_PRESSURE,
CONF_HUMIDITY,
CONF_GAS_RESISTANCE,
CONF_IAQ,
CONF_IAQ_STATIC,
CONF_IAQ_ACCURACY,
CONF_CO2_EQUIVALENT,
CONF_BREATH_VOC_EQUIVALENT,
]
CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(CONF_BME68X_BSEC2_ID): cv.use_id(BME68xBSEC2Component),
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
unit_of_measurement=UNIT_CELSIUS,
icon=ICON_THERMOMETER,
accuracy_decimals=1,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
).extend(
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
),
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
unit_of_measurement=UNIT_HECTOPASCAL,
icon=ICON_GAUGE,
accuracy_decimals=1,
device_class=DEVICE_CLASS_ATMOSPHERIC_PRESSURE,
state_class=STATE_CLASS_MEASUREMENT,
).extend(
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
),
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
unit_of_measurement=UNIT_PERCENT,
icon=ICON_WATER_PERCENT,
accuracy_decimals=1,
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
).extend(
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
),
cv.Optional(CONF_GAS_RESISTANCE): sensor.sensor_schema(
unit_of_measurement=UNIT_OHM,
icon=ICON_GAS_CYLINDER,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_IAQ): sensor.sensor_schema(
unit_of_measurement=UNIT_IAQ,
icon=ICON_GAUGE,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_IAQ_STATIC): sensor.sensor_schema(
unit_of_measurement=UNIT_IAQ,
icon=ICON_GAUGE,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_IAQ_ACCURACY): sensor.sensor_schema(
icon=ICON_ACCURACY,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_CO2_EQUIVALENT): sensor.sensor_schema(
unit_of_measurement=UNIT_PARTS_PER_MILLION,
icon=ICON_TEST_TUBE,
accuracy_decimals=1,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_BREATH_VOC_EQUIVALENT): sensor.sensor_schema(
unit_of_measurement=UNIT_PARTS_PER_MILLION,
icon=ICON_TEST_TUBE,
accuracy_decimals=1,
state_class=STATE_CLASS_MEASUREMENT,
),
}
)
async def setup_conf(config, key, hub):
if conf := config.get(key):
sens = await sensor.new_sensor(conf)
cg.add(getattr(hub, f"set_{key}_sensor")(sens))
if sample_rate := conf.get(CONF_SAMPLE_RATE):
cg.add(getattr(hub, f"set_{key}_sample_rate")(sample_rate))
async def to_code(config):
hub = await cg.get_variable(config[CONF_BME68X_BSEC2_ID])
for key in TYPES:
await setup_conf(config, key, hub)