# This file contains a schema for all supported sensors, binary sensors and
|
|
# inputs of the OpenTherm component.
|
|
|
|
from dataclasses import dataclass
|
|
from typing import Optional, TypeVar, Any
|
|
|
|
import esphome.config_validation as cv
|
|
from esphome.const import (
|
|
UNIT_CELSIUS,
|
|
UNIT_EMPTY,
|
|
UNIT_KILOWATT,
|
|
UNIT_MICROAMP,
|
|
UNIT_PERCENT,
|
|
UNIT_REVOLUTIONS_PER_MINUTE,
|
|
DEVICE_CLASS_COLD,
|
|
DEVICE_CLASS_CURRENT,
|
|
DEVICE_CLASS_EMPTY,
|
|
DEVICE_CLASS_HEAT,
|
|
DEVICE_CLASS_PRESSURE,
|
|
DEVICE_CLASS_PROBLEM,
|
|
DEVICE_CLASS_TEMPERATURE,
|
|
STATE_CLASS_MEASUREMENT,
|
|
STATE_CLASS_NONE,
|
|
STATE_CLASS_TOTAL_INCREASING,
|
|
)
|
|
|
|
|
|
@dataclass
|
|
class EntitySchema:
|
|
description: str
|
|
"""Description of the item, based on the OpenTherm spec"""
|
|
|
|
message: str
|
|
"""OpenTherm message id used to read or write the value"""
|
|
|
|
keep_updated: bool
|
|
"""Whether the value should be read or write repeatedly (True) or only during
|
|
the initialization phase (False)
|
|
"""
|
|
|
|
message_data: str
|
|
"""Instructions on how to interpret the data in the message
|
|
- flag8_[hb|lb]_[0-7]: data is a byte of single bit flags,
|
|
this flag is set in the high (hb) or low byte (lb),
|
|
at position 0 to 7
|
|
- u8_[hb|lb]: data is an unsigned 8-bit integer,
|
|
in the high (hb) or low byte (lb)
|
|
- s8_[hb|lb]: data is an signed 8-bit integer,
|
|
in the high (hb) or low byte (lb)
|
|
- f88: data is a signed fixed point value with
|
|
1 sign bit, 7 integer bits, 8 fractional bits
|
|
- u16: data is an unsigned 16-bit integer
|
|
- s16: data is a signed 16-bit integer
|
|
"""
|
|
|
|
|
|
TSchema = TypeVar("TSchema", bound=EntitySchema)
|
|
|
|
|
|
@dataclass
|
|
class SensorSchema(EntitySchema):
|
|
accuracy_decimals: int
|
|
state_class: str
|
|
unit_of_measurement: Optional[str] = None
|
|
icon: Optional[str] = None
|
|
device_class: Optional[str] = None
|
|
disabled_by_default: bool = False
|
|
order: Optional[int] = None
|
|
|
|
|
|
SENSORS: dict[str, SensorSchema] = {
|
|
"rel_mod_level": SensorSchema(
|
|
description="Relative modulation level",
|
|
unit_of_measurement=UNIT_PERCENT,
|
|
accuracy_decimals=2,
|
|
icon="mdi:percent",
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="MODULATION_LEVEL",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"ch_pressure": SensorSchema(
|
|
description="Water pressure in CH circuit",
|
|
unit_of_measurement="bar",
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_PRESSURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="CH_WATER_PRESSURE",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"dhw_flow_rate": SensorSchema(
|
|
description="Water flow rate in DHW circuit",
|
|
unit_of_measurement="l/min",
|
|
accuracy_decimals=2,
|
|
icon="mdi:waves-arrow-right",
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="DHW_FLOW_RATE",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"t_boiler": SensorSchema(
|
|
description="Boiler water temperature",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="FEED_TEMP",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"t_dhw": SensorSchema(
|
|
description="DHW temperature",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="DHW_TEMP",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"t_outside": SensorSchema(
|
|
description="Outside temperature",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="OUTSIDE_TEMP",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"t_ret": SensorSchema(
|
|
description="Return water temperature",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="RETURN_WATER_TEMP",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"t_storage": SensorSchema(
|
|
description="Solar storage temperature",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="SOLAR_STORE_TEMP",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"t_collector": SensorSchema(
|
|
description="Solar collector temperature",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="SOLAR_COLLECT_TEMP",
|
|
keep_updated=True,
|
|
message_data="s16",
|
|
),
|
|
"t_flow_ch2": SensorSchema(
|
|
description="Flow water temperature CH2 circuit",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="FEED_TEMP_CH2",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"t_dhw2": SensorSchema(
|
|
description="Domestic hot water temperature 2",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="DHW2_TEMP",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"t_exhaust": SensorSchema(
|
|
description="Boiler exhaust temperature",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="EXHAUST_TEMP",
|
|
keep_updated=True,
|
|
message_data="s16",
|
|
),
|
|
"fan_speed": SensorSchema(
|
|
description="Boiler fan speed",
|
|
unit_of_measurement=UNIT_REVOLUTIONS_PER_MINUTE,
|
|
accuracy_decimals=0,
|
|
icon="mdi:fan",
|
|
device_class=DEVICE_CLASS_EMPTY,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="FAN_SPEED",
|
|
keep_updated=True,
|
|
message_data="u8_lb_60",
|
|
),
|
|
"fan_speed_setpoint": SensorSchema(
|
|
description="Boiler fan speed setpoint",
|
|
unit_of_measurement=UNIT_REVOLUTIONS_PER_MINUTE,
|
|
accuracy_decimals=0,
|
|
icon="mdi:fan",
|
|
device_class=DEVICE_CLASS_EMPTY,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="FAN_SPEED",
|
|
keep_updated=True,
|
|
message_data="u8_hb_60",
|
|
),
|
|
"flame_current": SensorSchema(
|
|
description="Boiler flame current",
|
|
unit_of_measurement=UNIT_MICROAMP,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_CURRENT,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="FLAME_CURRENT",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"burner_starts": SensorSchema(
|
|
description="Number of starts burner",
|
|
accuracy_decimals=0,
|
|
icon="mdi:gas-burner",
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
message="BURNER_STARTS",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"ch_pump_starts": SensorSchema(
|
|
description="Number of starts CH pump",
|
|
accuracy_decimals=0,
|
|
icon="mdi:pump",
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
message="CH_PUMP_STARTS",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"dhw_pump_valve_starts": SensorSchema(
|
|
description="Number of starts DHW pump/valve",
|
|
accuracy_decimals=0,
|
|
icon="mdi:water-pump",
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
message="DHW_PUMP_STARTS",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"dhw_burner_starts": SensorSchema(
|
|
description="Number of starts burner during DHW mode",
|
|
accuracy_decimals=0,
|
|
icon="mdi:gas-burner",
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
message="DHW_BURNER_STARTS",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"burner_operation_hours": SensorSchema(
|
|
description="Number of hours that burner is in operation",
|
|
accuracy_decimals=0,
|
|
icon="mdi:clock-outline",
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
message="BURNER_HOURS",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"ch_pump_operation_hours": SensorSchema(
|
|
description="Number of hours that CH pump has been running",
|
|
accuracy_decimals=0,
|
|
icon="mdi:clock-outline",
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
message="CH_PUMP_HOURS",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"dhw_pump_valve_operation_hours": SensorSchema(
|
|
description="Number of hours that DHW pump has been running or DHW valve has been opened",
|
|
accuracy_decimals=0,
|
|
icon="mdi:clock-outline",
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
message="DHW_PUMP_HOURS",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"dhw_burner_operation_hours": SensorSchema(
|
|
description="Number of hours that burner is in operation during DHW mode",
|
|
accuracy_decimals=0,
|
|
icon="mdi:clock-outline",
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
message="DHW_BURNER_HOURS",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"t_dhw_set_ub": SensorSchema(
|
|
description="Upper bound for adjustment of DHW setpoint",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="DHW_BOUNDS",
|
|
keep_updated=False,
|
|
message_data="s8_hb",
|
|
),
|
|
"t_dhw_set_lb": SensorSchema(
|
|
description="Lower bound for adjustment of DHW setpoint",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="DHW_BOUNDS",
|
|
keep_updated=False,
|
|
message_data="s8_lb",
|
|
),
|
|
"max_t_set_ub": SensorSchema(
|
|
description="Upper bound for adjustment of max CH setpoint",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="CH_BOUNDS",
|
|
keep_updated=False,
|
|
message_data="s8_hb",
|
|
),
|
|
"max_t_set_lb": SensorSchema(
|
|
description="Lower bound for adjustment of max CH setpoint",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="CH_BOUNDS",
|
|
keep_updated=False,
|
|
message_data="s8_lb",
|
|
),
|
|
"t_dhw_set": SensorSchema(
|
|
description="Domestic hot water temperature setpoint",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="DHW_SETPOINT",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"max_t_set": SensorSchema(
|
|
description="Maximum allowable CH water setpoint",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="MAX_CH_SETPOINT",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
),
|
|
"oem_fault_code": SensorSchema(
|
|
description="OEM fault code",
|
|
unit_of_measurement=UNIT_EMPTY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_NONE,
|
|
message="FAULT_FLAGS",
|
|
keep_updated=True,
|
|
message_data="u8_lb",
|
|
),
|
|
"oem_diagnostic_code": SensorSchema(
|
|
description="OEM diagnostic code",
|
|
unit_of_measurement=UNIT_EMPTY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_NONE,
|
|
message="OEM_DIAGNOSTIC",
|
|
keep_updated=True,
|
|
message_data="u16",
|
|
),
|
|
"max_capacity": SensorSchema(
|
|
description="Maximum boiler capacity (KW)",
|
|
unit_of_measurement=UNIT_KILOWATT,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
disabled_by_default=True,
|
|
message="MAX_BOILER_CAPACITY",
|
|
keep_updated=False,
|
|
message_data="u8_hb",
|
|
),
|
|
"min_mod_level": SensorSchema(
|
|
description="Minimum modulation level",
|
|
unit_of_measurement=UNIT_PERCENT,
|
|
accuracy_decimals=0,
|
|
icon="mdi:percent",
|
|
disabled_by_default=True,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
message="MAX_BOILER_CAPACITY",
|
|
keep_updated=False,
|
|
message_data="u8_lb",
|
|
),
|
|
"opentherm_version_device": SensorSchema(
|
|
description="Version of OpenTherm implemented by device",
|
|
unit_of_measurement=UNIT_EMPTY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_NONE,
|
|
disabled_by_default=True,
|
|
message="OT_VERSION_DEVICE",
|
|
keep_updated=False,
|
|
message_data="f88",
|
|
order=2,
|
|
),
|
|
"device_type": SensorSchema(
|
|
description="Device product type",
|
|
unit_of_measurement=UNIT_EMPTY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_NONE,
|
|
disabled_by_default=True,
|
|
message="VERSION_DEVICE",
|
|
keep_updated=False,
|
|
message_data="u8_hb",
|
|
order=0,
|
|
),
|
|
"device_version": SensorSchema(
|
|
description="Device product version",
|
|
unit_of_measurement=UNIT_EMPTY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_NONE,
|
|
disabled_by_default=True,
|
|
message="VERSION_DEVICE",
|
|
keep_updated=False,
|
|
message_data="u8_lb",
|
|
order=0,
|
|
),
|
|
"device_id": SensorSchema(
|
|
description="Device ID code",
|
|
unit_of_measurement=UNIT_EMPTY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_NONE,
|
|
disabled_by_default=True,
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="u8_lb",
|
|
order=4,
|
|
),
|
|
"otc_hc_ratio_ub": SensorSchema(
|
|
description="OTC heat curve ratio upper bound",
|
|
unit_of_measurement=UNIT_EMPTY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_NONE,
|
|
disabled_by_default=True,
|
|
message="OTC_CURVE_BOUNDS",
|
|
keep_updated=False,
|
|
message_data="u8_hb",
|
|
),
|
|
"otc_hc_ratio_lb": SensorSchema(
|
|
description="OTC heat curve ratio lower bound",
|
|
unit_of_measurement=UNIT_EMPTY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_NONE,
|
|
disabled_by_default=True,
|
|
message="OTC_CURVE_BOUNDS",
|
|
keep_updated=False,
|
|
message_data="u8_lb",
|
|
),
|
|
}
|
|
|
|
|
|
@dataclass
|
|
class BinarySensorSchema(EntitySchema):
|
|
icon: Optional[str] = None
|
|
device_class: Optional[str] = None
|
|
order: Optional[int] = None
|
|
|
|
|
|
BINARY_SENSORS: dict[str, BinarySensorSchema] = {
|
|
"fault_indication": BinarySensorSchema(
|
|
description="Status: Fault indication",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_lb_0",
|
|
),
|
|
"ch_active": BinarySensorSchema(
|
|
description="Status: Central Heating active",
|
|
device_class=DEVICE_CLASS_HEAT,
|
|
icon="mdi:radiator",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_lb_1",
|
|
),
|
|
"dhw_active": BinarySensorSchema(
|
|
description="Status: Domestic Hot Water active",
|
|
device_class=DEVICE_CLASS_HEAT,
|
|
icon="mdi:faucet",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_lb_2",
|
|
),
|
|
"flame_on": BinarySensorSchema(
|
|
description="Status: Flame on",
|
|
device_class=DEVICE_CLASS_HEAT,
|
|
icon="mdi:fire",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_lb_3",
|
|
),
|
|
"cooling_active": BinarySensorSchema(
|
|
description="Status: Cooling active",
|
|
device_class=DEVICE_CLASS_COLD,
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_lb_4",
|
|
),
|
|
"ch2_active": BinarySensorSchema(
|
|
description="Status: Central Heating 2 active",
|
|
device_class=DEVICE_CLASS_HEAT,
|
|
icon="mdi:radiator",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_lb_5",
|
|
),
|
|
"diagnostic_indication": BinarySensorSchema(
|
|
description="Status: Diagnostic event",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_lb_6",
|
|
),
|
|
"electricity_production": BinarySensorSchema(
|
|
description="Status: Electricity production",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_lb_7",
|
|
),
|
|
"dhw_present": BinarySensorSchema(
|
|
description="Configuration: DHW present",
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_0",
|
|
order=4,
|
|
),
|
|
"control_type_on_off": BinarySensorSchema(
|
|
description="Configuration: Control type is on/off",
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_1",
|
|
order=4,
|
|
),
|
|
"cooling_supported": BinarySensorSchema(
|
|
description="Configuration: Cooling supported",
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_2",
|
|
order=4,
|
|
),
|
|
"dhw_storage_tank": BinarySensorSchema(
|
|
description="Configuration: DHW storage tank",
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_3",
|
|
order=4,
|
|
),
|
|
"controller_pump_control_allowed": BinarySensorSchema(
|
|
description="Configuration: Controller pump control allowed",
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_4",
|
|
order=4,
|
|
),
|
|
"ch2_present": BinarySensorSchema(
|
|
description="Configuration: CH2 present",
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_5",
|
|
order=4,
|
|
),
|
|
"water_filling": BinarySensorSchema(
|
|
description="Configuration: Remote water filling",
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_6",
|
|
order=4,
|
|
),
|
|
"heat_mode": BinarySensorSchema(
|
|
description="Configuration: Heating or cooling",
|
|
message="DEVICE_CONFIG",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_7",
|
|
order=4,
|
|
),
|
|
"dhw_setpoint_transfer_enabled": BinarySensorSchema(
|
|
description="Remote boiler parameters: DHW setpoint transfer enabled",
|
|
message="REMOTE",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_0",
|
|
),
|
|
"max_ch_setpoint_transfer_enabled": BinarySensorSchema(
|
|
description="Remote boiler parameters: CH maximum setpoint transfer enabled",
|
|
message="REMOTE",
|
|
keep_updated=False,
|
|
message_data="flag8_hb_1",
|
|
),
|
|
"dhw_setpoint_rw": BinarySensorSchema(
|
|
description="Remote boiler parameters: DHW setpoint read/write",
|
|
message="REMOTE",
|
|
keep_updated=False,
|
|
message_data="flag8_lb_0",
|
|
),
|
|
"max_ch_setpoint_rw": BinarySensorSchema(
|
|
description="Remote boiler parameters: CH maximum setpoint read/write",
|
|
message="REMOTE",
|
|
keep_updated=False,
|
|
message_data="flag8_lb_1",
|
|
),
|
|
"service_request": BinarySensorSchema(
|
|
description="Service required",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="FAULT_FLAGS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_0",
|
|
),
|
|
"lockout_reset": BinarySensorSchema(
|
|
description="Lockout Reset",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="FAULT_FLAGS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_1",
|
|
),
|
|
"low_water_pressure": BinarySensorSchema(
|
|
description="Low water pressure fault",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="FAULT_FLAGS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_2",
|
|
),
|
|
"flame_fault": BinarySensorSchema(
|
|
description="Flame fault",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="FAULT_FLAGS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_3",
|
|
),
|
|
"air_pressure_fault": BinarySensorSchema(
|
|
description="Air pressure fault",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="FAULT_FLAGS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_4",
|
|
),
|
|
"water_over_temp": BinarySensorSchema(
|
|
description="Water overtemperature",
|
|
device_class=DEVICE_CLASS_PROBLEM,
|
|
message="FAULT_FLAGS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_5",
|
|
),
|
|
}
|
|
|
|
|
|
@dataclass
|
|
class SwitchSchema(EntitySchema):
|
|
default_mode: Optional[str] = None
|
|
|
|
|
|
SWITCHES: dict[str, SwitchSchema] = {
|
|
"ch_enable": SwitchSchema(
|
|
description="Central Heating enabled",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_0",
|
|
default_mode="restore_default_off",
|
|
),
|
|
"dhw_enable": SwitchSchema(
|
|
description="Domestic Hot Water enabled",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_1",
|
|
default_mode="restore_default_off",
|
|
),
|
|
"cooling_enable": SwitchSchema(
|
|
description="Cooling enabled",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_2",
|
|
default_mode="restore_default_off",
|
|
),
|
|
"otc_active": SwitchSchema(
|
|
description="Outside temperature compensation active",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_3",
|
|
default_mode="restore_default_off",
|
|
),
|
|
"ch2_active": SwitchSchema(
|
|
description="Central Heating 2 active",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_4",
|
|
default_mode="restore_default_off",
|
|
),
|
|
"summer_mode_active": SwitchSchema(
|
|
description="Summer mode active",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_5",
|
|
default_mode="restore_default_off",
|
|
),
|
|
"dhw_block": SwitchSchema(
|
|
description="DHW blocked",
|
|
message="STATUS",
|
|
keep_updated=True,
|
|
message_data="flag8_hb_6",
|
|
default_mode="restore_default_off",
|
|
),
|
|
}
|
|
|
|
|
|
@dataclass
|
|
class AutoConfigure:
|
|
message: str
|
|
message_data: str
|
|
|
|
|
|
@dataclass
|
|
class InputSchema(EntitySchema):
|
|
unit_of_measurement: str
|
|
step: float
|
|
range: tuple[int, int]
|
|
icon: Optional[str] = None
|
|
auto_max_value: Optional[AutoConfigure] = None
|
|
auto_min_value: Optional[AutoConfigure] = None
|
|
|
|
|
|
INPUTS: dict[str, InputSchema] = {
|
|
"t_set": InputSchema(
|
|
description="Control setpoint: temperature setpoint for the boiler's supply water",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
step=0.1,
|
|
message="CH_SETPOINT",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(0, 100),
|
|
auto_max_value=AutoConfigure(message="MAX_CH_SETPOINT", message_data="f88"),
|
|
),
|
|
"t_set_ch2": InputSchema(
|
|
description="Control setpoint 2: temperature setpoint for the boiler's supply water on the second heating circuit",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
step=0.1,
|
|
message="CH2_SETPOINT",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(0, 100),
|
|
auto_max_value=AutoConfigure(message="MAX_CH_SETPOINT", message_data="f88"),
|
|
),
|
|
"cooling_control": InputSchema(
|
|
description="Cooling control signal",
|
|
unit_of_measurement=UNIT_PERCENT,
|
|
step=1.0,
|
|
message="COOLING_CONTROL",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(0, 100),
|
|
),
|
|
"t_dhw_set": InputSchema(
|
|
description="Domestic hot water temperature setpoint",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
step=0.1,
|
|
message="DHW_SETPOINT",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(0, 127),
|
|
auto_min_value=AutoConfigure(message="DHW_BOUNDS", message_data="s8_lb"),
|
|
auto_max_value=AutoConfigure(message="DHW_BOUNDS", message_data="s8_hb"),
|
|
),
|
|
"max_t_set": InputSchema(
|
|
description="Maximum allowable CH water setpoint",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
step=0.1,
|
|
message="MAX_CH_SETPOINT",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(0, 127),
|
|
auto_min_value=AutoConfigure(message="CH_BOUNDS", message_data="s8_lb"),
|
|
auto_max_value=AutoConfigure(message="CH_BOUNDS", message_data="s8_hb"),
|
|
),
|
|
"t_room_set": InputSchema(
|
|
description="Current room temperature setpoint (informational)",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
step=0.1,
|
|
message="ROOM_SETPOINT",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(-40, 127),
|
|
),
|
|
"t_room_set_ch2": InputSchema(
|
|
description="Current room temperature setpoint on CH2 (informational)",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
step=0.1,
|
|
message="ROOM_SETPOINT_CH2",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(-40, 127),
|
|
),
|
|
"t_room": InputSchema(
|
|
description="Current sensed room temperature (informational)",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
step=0.1,
|
|
message="ROOM_TEMP",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(-40, 127),
|
|
),
|
|
"max_rel_mod_level": InputSchema(
|
|
description="Maximum relative modulation level",
|
|
unit_of_measurement=UNIT_PERCENT,
|
|
step=1,
|
|
icon="mdi:percent",
|
|
message="MAX_MODULATION_LEVEL",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(0, 100),
|
|
),
|
|
"otc_hc_ratio": InputSchema(
|
|
description="OTC heat curve ratio",
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
step=0.1,
|
|
message="OTC_CURVE_RATIO",
|
|
keep_updated=True,
|
|
message_data="f88",
|
|
range=(0, 127),
|
|
auto_min_value=AutoConfigure(message="OTC_CURVE_BOUNDS", message_data="u8_lb"),
|
|
auto_max_value=AutoConfigure(message="OTC_CURVE_BOUNDS", message_data="u8_hb"),
|
|
),
|
|
}
|
|
|
|
|
|
@dataclass
|
|
class SettingSchema(EntitySchema):
|
|
backing_type: str
|
|
validation_schema: cv.Schema
|
|
default_value: Any
|
|
order: Optional[int] = None
|
|
|
|
|
|
SETTINGS: dict[str, SettingSchema] = {
|
|
"controller_product_type": SettingSchema(
|
|
description="Controller product type",
|
|
message="VERSION_CONTROLLER",
|
|
keep_updated=False,
|
|
message_data="u8_hb",
|
|
backing_type="uint8_t",
|
|
validation_schema=cv.int_range(min=0, max=255),
|
|
default_value=0,
|
|
order=1,
|
|
),
|
|
"controller_product_version": SettingSchema(
|
|
description="Controller product version",
|
|
message="VERSION_CONTROLLER",
|
|
keep_updated=False,
|
|
message_data="u8_lb",
|
|
backing_type="uint8_t",
|
|
validation_schema=cv.int_range(min=0, max=255),
|
|
default_value=0,
|
|
order=1,
|
|
),
|
|
"opentherm_version_controller": SettingSchema(
|
|
description="Version of OpenTherm implemented by controller",
|
|
message="OT_VERSION_CONTROLLER",
|
|
keep_updated=False,
|
|
message_data="f88",
|
|
backing_type="float",
|
|
validation_schema=cv.positive_float,
|
|
default_value=0,
|
|
order=3,
|
|
),
|
|
"controller_configuration": SettingSchema(
|
|
description="Controller configuration",
|
|
message="CONTROLLER_CONFIG",
|
|
keep_updated=False,
|
|
message_data="u8_hb",
|
|
backing_type="uint8_t",
|
|
validation_schema=cv.int_range(min=0, max=255),
|
|
default_value=0,
|
|
order=5,
|
|
),
|
|
"controller_id": SettingSchema(
|
|
description="Controller ID code",
|
|
message="CONTROLLER_CONFIG",
|
|
keep_updated=False,
|
|
message_data="u8_lb",
|
|
backing_type="uint8_t",
|
|
validation_schema=cv.int_range(min=0, max=255),
|
|
default_value=0,
|
|
order=5,
|
|
),
|
|
}
|