# This file contains a schema for all supported sensors, binary sensors and
# inputs of the OpenTherm component.
from dataclasses import dataclass
from typing import Optional, TypeVar, Any
import esphome.config_validation as cv
from esphome.const import (
UNIT_CELSIUS,
UNIT_EMPTY,
UNIT_KILOWATT,
UNIT_MICROAMP,
UNIT_PERCENT,
UNIT_REVOLUTIONS_PER_MINUTE,
DEVICE_CLASS_COLD,
DEVICE_CLASS_CURRENT,
DEVICE_CLASS_EMPTY,
DEVICE_CLASS_HEAT,
DEVICE_CLASS_PRESSURE,
DEVICE_CLASS_PROBLEM,
DEVICE_CLASS_TEMPERATURE,
STATE_CLASS_MEASUREMENT,
STATE_CLASS_NONE,
STATE_CLASS_TOTAL_INCREASING,
)
@dataclass
class EntitySchema:
description: str
"""Description of the item, based on the OpenTherm spec"""
message: str
"""OpenTherm message id used to read or write the value"""
keep_updated: bool
"""Whether the value should be read or write repeatedly (True) or only during
the initialization phase (False)
"""
message_data: str
"""Instructions on how to interpret the data in the message
- flag8_[hb|lb]_[0-7]: data is a byte of single bit flags,
this flag is set in the high (hb) or low byte (lb),
at position 0 to 7
- u8_[hb|lb]: data is an unsigned 8-bit integer,
in the high (hb) or low byte (lb)
- s8_[hb|lb]: data is an signed 8-bit integer,
in the high (hb) or low byte (lb)
- f88: data is a signed fixed point value with
1 sign bit, 7 integer bits, 8 fractional bits
- u16: data is an unsigned 16-bit integer
- s16: data is a signed 16-bit integer
"""
TSchema = TypeVar("TSchema", bound=EntitySchema)
@dataclass
class SensorSchema(EntitySchema):
accuracy_decimals: int
state_class: str
unit_of_measurement: Optional[str] = None
icon: Optional[str] = None
device_class: Optional[str] = None
disabled_by_default: bool = False
order: Optional[int] = None
SENSORS: dict[str, SensorSchema] = {
"rel_mod_level": SensorSchema(
description="Relative modulation level",
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=2,
icon="mdi:percent",
state_class=STATE_CLASS_MEASUREMENT,
message="MODULATION_LEVEL",
keep_updated=True,
message_data="f88",
),
"ch_pressure": SensorSchema(
description="Water pressure in CH circuit",
unit_of_measurement="bar",
accuracy_decimals=2,
device_class=DEVICE_CLASS_PRESSURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_WATER_PRESSURE",
keep_updated=True,
message_data="f88",
),
"dhw_flow_rate": SensorSchema(
description="Water flow rate in DHW circuit",
unit_of_measurement="l/min",
accuracy_decimals=2,
icon="mdi:waves-arrow-right",
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_FLOW_RATE",
keep_updated=True,
message_data="f88",
),
"t_boiler": SensorSchema(
description="Boiler water temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="FEED_TEMP",
keep_updated=True,
message_data="f88",
),
"t_dhw": SensorSchema(
description="DHW temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_TEMP",
keep_updated=True,
message_data="f88",
),
"t_outside": SensorSchema(
description="Outside temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="OUTSIDE_TEMP",
keep_updated=True,
message_data="f88",
),
"t_ret": SensorSchema(
description="Return water temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="RETURN_WATER_TEMP",
keep_updated=True,
message_data="f88",
),
"t_storage": SensorSchema(
description="Solar storage temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="SOLAR_STORE_TEMP",
keep_updated=True,
message_data="f88",
),
"t_collector": SensorSchema(
description="Solar collector temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="SOLAR_COLLECT_TEMP",
keep_updated=True,
message_data="s16",
),
"t_flow_ch2": SensorSchema(
description="Flow water temperature CH2 circuit",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="FEED_TEMP_CH2",
keep_updated=True,
message_data="f88",
),
"t_dhw2": SensorSchema(
description="Domestic hot water temperature 2",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW2_TEMP",
keep_updated=True,
message_data="f88",
),
"t_exhaust": SensorSchema(
description="Boiler exhaust temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="EXHAUST_TEMP",
keep_updated=True,
message_data="s16",
),
"fan_speed": SensorSchema(
description="Boiler fan speed",
unit_of_measurement=UNIT_REVOLUTIONS_PER_MINUTE,
accuracy_decimals=0,
icon="mdi:fan",
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_MEASUREMENT,
message="FAN_SPEED",
keep_updated=True,
message_data="u8_lb_60",
),
"fan_speed_setpoint": SensorSchema(
description="Boiler fan speed setpoint",
unit_of_measurement=UNIT_REVOLUTIONS_PER_MINUTE,
accuracy_decimals=0,
icon="mdi:fan",
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_MEASUREMENT,
message="FAN_SPEED",
keep_updated=True,
message_data="u8_hb_60",
),
"flame_current": SensorSchema(
description="Boiler flame current",
unit_of_measurement=UNIT_MICROAMP,
accuracy_decimals=0,
device_class=DEVICE_CLASS_CURRENT,
state_class=STATE_CLASS_MEASUREMENT,
message="FLAME_CURRENT",
keep_updated=True,
message_data="f88",
),
"burner_starts": SensorSchema(
description="Number of starts burner",
accuracy_decimals=0,
icon="mdi:gas-burner",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="BURNER_STARTS",
keep_updated=True,
message_data="u16",
),
"ch_pump_starts": SensorSchema(
description="Number of starts CH pump",
accuracy_decimals=0,
icon="mdi:pump",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="CH_PUMP_STARTS",
keep_updated=True,
message_data="u16",
),
"dhw_pump_valve_starts": SensorSchema(
description="Number of starts DHW pump/valve",
accuracy_decimals=0,
icon="mdi:water-pump",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_PUMP_STARTS",
keep_updated=True,
message_data="u16",
),
"dhw_burner_starts": SensorSchema(
description="Number of starts burner during DHW mode",
accuracy_decimals=0,
icon="mdi:gas-burner",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_BURNER_STARTS",
keep_updated=True,
message_data="u16",
),
"burner_operation_hours": SensorSchema(
description="Number of hours that burner is in operation",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="BURNER_HOURS",
keep_updated=True,
message_data="u16",
),
"ch_pump_operation_hours": SensorSchema(
description="Number of hours that CH pump has been running",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="CH_PUMP_HOURS",
keep_updated=True,
message_data="u16",
),
"dhw_pump_valve_operation_hours": SensorSchema(
description="Number of hours that DHW pump has been running or DHW valve has been opened",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_PUMP_HOURS",
keep_updated=True,
message_data="u16",
),
"dhw_burner_operation_hours": SensorSchema(
description="Number of hours that burner is in operation during DHW mode",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_BURNER_HOURS",
keep_updated=True,
message_data="u16",
),
"t_dhw_set_ub": SensorSchema(
description="Upper bound for adjustment of DHW setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_BOUNDS",
keep_updated=False,
message_data="s8_hb",
),
"t_dhw_set_lb": SensorSchema(
description="Lower bound for adjustment of DHW setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_BOUNDS",
keep_updated=False,
message_data="s8_lb",
),
"max_t_set_ub": SensorSchema(
description="Upper bound for adjustment of max CH setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_BOUNDS",
keep_updated=False,
message_data="s8_hb",
),
"max_t_set_lb": SensorSchema(
description="Lower bound for adjustment of max CH setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_BOUNDS",
keep_updated=False,
message_data="s8_lb",
),
"t_dhw_set": SensorSchema(
description="Domestic hot water temperature setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_SETPOINT",
keep_updated=True,
message_data="f88",
),
"max_t_set": SensorSchema(
description="Maximum allowable CH water setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="MAX_CH_SETPOINT",
keep_updated=True,
message_data="f88",
),
"oem_fault_code": SensorSchema(
description="OEM fault code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
message="FAULT_FLAGS",
keep_updated=True,
message_data="u8_lb",
),
"oem_diagnostic_code": SensorSchema(
description="OEM diagnostic code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
message="OEM_DIAGNOSTIC",
keep_updated=True,
message_data="u16",
),
"max_capacity": SensorSchema(
description="Maximum boiler capacity (KW)",
unit_of_measurement=UNIT_KILOWATT,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
disabled_by_default=True,
message="MAX_BOILER_CAPACITY",
keep_updated=False,
message_data="u8_hb",
),
"min_mod_level": SensorSchema(
description="Minimum modulation level",
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=0,
icon="mdi:percent",
disabled_by_default=True,
state_class=STATE_CLASS_MEASUREMENT,
message="MAX_BOILER_CAPACITY",
keep_updated=False,
message_data="u8_lb",
),
"opentherm_version_device": SensorSchema(
description="Version of OpenTherm implemented by device",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OT_VERSION_DEVICE",
keep_updated=False,
message_data="f88",
order=2,
),
"device_type": SensorSchema(
description="Device product type",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="VERSION_DEVICE",
keep_updated=False,
message_data="u8_hb",
order=0,
),
"device_version": SensorSchema(
description="Device product version",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="VERSION_DEVICE",
keep_updated=False,
message_data="u8_lb",
order=0,
),
"device_id": SensorSchema(
description="Device ID code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="DEVICE_CONFIG",
keep_updated=False,
message_data="u8_lb",
order=4,
),
"otc_hc_ratio_ub": SensorSchema(
description="OTC heat curve ratio upper bound",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OTC_CURVE_BOUNDS",
keep_updated=False,
message_data="u8_hb",
),
"otc_hc_ratio_lb": SensorSchema(
description="OTC heat curve ratio lower bound",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OTC_CURVE_BOUNDS",
keep_updated=False,
message_data="u8_lb",
),
}
@dataclass
class BinarySensorSchema(EntitySchema):
icon: Optional[str] = None
device_class: Optional[str] = None
order: Optional[int] = None
BINARY_SENSORS: dict[str, BinarySensorSchema] = {
"fault_indication": BinarySensorSchema(
description="Status: Fault indication",
device_class=DEVICE_CLASS_PROBLEM,
message="STATUS",
keep_updated=True,
message_data="flag8_lb_0",
),
"ch_active": BinarySensorSchema(
description="Status: Central Heating active",
device_class=DEVICE_CLASS_HEAT,
icon="mdi:radiator",
message="STATUS",
keep_updated=True,
message_data="flag8_lb_1",
),
"dhw_active": BinarySensorSchema(
description="Status: Domestic Hot Water active",
device_class=DEVICE_CLASS_HEAT,
icon="mdi:faucet",
message="STATUS",
keep_updated=True,
message_data="flag8_lb_2",
),
"flame_on": BinarySensorSchema(
description="Status: Flame on",
device_class=DEVICE_CLASS_HEAT,
icon="mdi:fire",
message="STATUS",
keep_updated=True,
message_data="flag8_lb_3",
),
"cooling_active": BinarySensorSchema(
description="Status: Cooling active",
device_class=DEVICE_CLASS_COLD,
message="STATUS",
keep_updated=True,
message_data="flag8_lb_4",
),
"ch2_active": BinarySensorSchema(
description="Status: Central Heating 2 active",
device_class=DEVICE_CLASS_HEAT,
icon="mdi:radiator",
message="STATUS",
keep_updated=True,
message_data="flag8_lb_5",
),
"diagnostic_indication": BinarySensorSchema(
description="Status: Diagnostic event",
device_class=DEVICE_CLASS_PROBLEM,
message="STATUS",
keep_updated=True,
message_data="flag8_lb_6",
),
"electricity_production": BinarySensorSchema(
description="Status: Electricity production",
device_class=DEVICE_CLASS_PROBLEM,
message="STATUS",
keep_updated=True,
message_data="flag8_lb_7",
),
"dhw_present": BinarySensorSchema(
description="Configuration: DHW present",
message="DEVICE_CONFIG",
keep_updated=False,
message_data="flag8_hb_0",
order=4,
),
"control_type_on_off": BinarySensorSchema(
description="Configuration: Control type is on/off",
message="DEVICE_CONFIG",
keep_updated=False,
message_data="flag8_hb_1",
order=4,
),
"cooling_supported": BinarySensorSchema(
description="Configuration: Cooling supported",
message="DEVICE_CONFIG",
keep_updated=False,
message_data="flag8_hb_2",
order=4,
),
"dhw_storage_tank": BinarySensorSchema(
description="Configuration: DHW storage tank",
message="DEVICE_CONFIG",
keep_updated=False,
message_data="flag8_hb_3",
order=4,
),
"controller_pump_control_allowed": BinarySensorSchema(
description="Configuration: Controller pump control allowed",
message="DEVICE_CONFIG",
keep_updated=False,
message_data="flag8_hb_4",
order=4,
),
"ch2_present": BinarySensorSchema(
description="Configuration: CH2 present",
message="DEVICE_CONFIG",
keep_updated=False,
message_data="flag8_hb_5",
order=4,
),
"water_filling": BinarySensorSchema(
description="Configuration: Remote water filling",
message="DEVICE_CONFIG",
keep_updated=False,
message_data="flag8_hb_6",
order=4,
),
"heat_mode": BinarySensorSchema(
description="Configuration: Heating or cooling",
message="DEVICE_CONFIG",
keep_updated=False,
message_data="flag8_hb_7",
order=4,
),
"dhw_setpoint_transfer_enabled": BinarySensorSchema(
description="Remote boiler parameters: DHW setpoint transfer enabled",
message="REMOTE",
keep_updated=False,
message_data="flag8_hb_0",
),
"max_ch_setpoint_transfer_enabled": BinarySensorSchema(
description="Remote boiler parameters: CH maximum setpoint transfer enabled",
message="REMOTE",
keep_updated=False,
message_data="flag8_hb_1",
),
"dhw_setpoint_rw": BinarySensorSchema(
description="Remote boiler parameters: DHW setpoint read/write",
message="REMOTE",
keep_updated=False,
message_data="flag8_lb_0",
),
"max_ch_setpoint_rw": BinarySensorSchema(
description="Remote boiler parameters: CH maximum setpoint read/write",
message="REMOTE",
keep_updated=False,
message_data="flag8_lb_1",
),
"service_request": BinarySensorSchema(
description="Service required",
device_class=DEVICE_CLASS_PROBLEM,
message="FAULT_FLAGS",
keep_updated=True,
message_data="flag8_hb_0",
),
"lockout_reset": BinarySensorSchema(
description="Lockout Reset",
device_class=DEVICE_CLASS_PROBLEM,
message="FAULT_FLAGS",
keep_updated=True,
message_data="flag8_hb_1",
),
"low_water_pressure": BinarySensorSchema(
description="Low water pressure fault",
device_class=DEVICE_CLASS_PROBLEM,
message="FAULT_FLAGS",
keep_updated=True,
message_data="flag8_hb_2",
),
"flame_fault": BinarySensorSchema(
description="Flame fault",
device_class=DEVICE_CLASS_PROBLEM,
message="FAULT_FLAGS",
keep_updated=True,
message_data="flag8_hb_3",
),
"air_pressure_fault": BinarySensorSchema(
description="Air pressure fault",
device_class=DEVICE_CLASS_PROBLEM,
message="FAULT_FLAGS",
keep_updated=True,
message_data="flag8_hb_4",
),
"water_over_temp": BinarySensorSchema(
description="Water overtemperature",
device_class=DEVICE_CLASS_PROBLEM,
message="FAULT_FLAGS",
keep_updated=True,
message_data="flag8_hb_5",
),
}
@dataclass
class SwitchSchema(EntitySchema):
default_mode: Optional[str] = None
SWITCHES: dict[str, SwitchSchema] = {
"ch_enable": SwitchSchema(
description="Central Heating enabled",
message="STATUS",
keep_updated=True,
message_data="flag8_hb_0",
default_mode="restore_default_off",
),
"dhw_enable": SwitchSchema(
description="Domestic Hot Water enabled",
message="STATUS",
keep_updated=True,
message_data="flag8_hb_1",
default_mode="restore_default_off",
),
"cooling_enable": SwitchSchema(
description="Cooling enabled",
message="STATUS",
keep_updated=True,
message_data="flag8_hb_2",
default_mode="restore_default_off",
),
"otc_active": SwitchSchema(
description="Outside temperature compensation active",
message="STATUS",
keep_updated=True,
message_data="flag8_hb_3",
default_mode="restore_default_off",
),
"ch2_active": SwitchSchema(
description="Central Heating 2 active",
message="STATUS",
keep_updated=True,
message_data="flag8_hb_4",
default_mode="restore_default_off",
),
"summer_mode_active": SwitchSchema(
description="Summer mode active",
message="STATUS",
keep_updated=True,
message_data="flag8_hb_5",
default_mode="restore_default_off",
),
"dhw_block": SwitchSchema(
description="DHW blocked",
message="STATUS",
keep_updated=True,
message_data="flag8_hb_6",
default_mode="restore_default_off",
),
}
@dataclass
class AutoConfigure:
message: str
message_data: str
@dataclass
class InputSchema(EntitySchema):
unit_of_measurement: str
step: float
range: tuple[int, int]
icon: Optional[str] = None
auto_max_value: Optional[AutoConfigure] = None
auto_min_value: Optional[AutoConfigure] = None
INPUTS: dict[str, InputSchema] = {
"t_set": InputSchema(
description="Control setpoint: temperature setpoint for the boiler's supply water",
unit_of_measurement=UNIT_CELSIUS,
step=0.1,
message="CH_SETPOINT",
keep_updated=True,
message_data="f88",
range=(0, 100),
auto_max_value=AutoConfigure(message="MAX_CH_SETPOINT", message_data="f88"),
),
"t_set_ch2": InputSchema(
description="Control setpoint 2: temperature setpoint for the boiler's supply water on the second heating circuit",
unit_of_measurement=UNIT_CELSIUS,
step=0.1,
message="CH2_SETPOINT",
keep_updated=True,
message_data="f88",
range=(0, 100),
auto_max_value=AutoConfigure(message="MAX_CH_SETPOINT", message_data="f88"),
),
"cooling_control": InputSchema(
description="Cooling control signal",
unit_of_measurement=UNIT_PERCENT,
step=1.0,
message="COOLING_CONTROL",
keep_updated=True,
message_data="f88",
range=(0, 100),
),
"t_dhw_set": InputSchema(
description="Domestic hot water temperature setpoint",
unit_of_measurement=UNIT_CELSIUS,
step=0.1,
message="DHW_SETPOINT",
keep_updated=True,
message_data="f88",
range=(0, 127),
auto_min_value=AutoConfigure(message="DHW_BOUNDS", message_data="s8_lb"),
auto_max_value=AutoConfigure(message="DHW_BOUNDS", message_data="s8_hb"),
),
"max_t_set": InputSchema(
description="Maximum allowable CH water setpoint",
unit_of_measurement=UNIT_CELSIUS,
step=0.1,
message="MAX_CH_SETPOINT",
keep_updated=True,
message_data="f88",
range=(0, 127),
auto_min_value=AutoConfigure(message="CH_BOUNDS", message_data="s8_lb"),
auto_max_value=AutoConfigure(message="CH_BOUNDS", message_data="s8_hb"),
),
"t_room_set": InputSchema(
description="Current room temperature setpoint (informational)",
unit_of_measurement=UNIT_CELSIUS,
step=0.1,
message="ROOM_SETPOINT",
keep_updated=True,
message_data="f88",
range=(-40, 127),
),
"t_room_set_ch2": InputSchema(
description="Current room temperature setpoint on CH2 (informational)",
unit_of_measurement=UNIT_CELSIUS,
step=0.1,
message="ROOM_SETPOINT_CH2",
keep_updated=True,
message_data="f88",
range=(-40, 127),
),
"t_room": InputSchema(
description="Current sensed room temperature (informational)",
unit_of_measurement=UNIT_CELSIUS,
step=0.1,
message="ROOM_TEMP",
keep_updated=True,
message_data="f88",
range=(-40, 127),
),
"max_rel_mod_level": InputSchema(
description="Maximum relative modulation level",
unit_of_measurement=UNIT_PERCENT,
step=1,
icon="mdi:percent",
message="MAX_MODULATION_LEVEL",
keep_updated=True,
message_data="f88",
range=(0, 100),
),
"otc_hc_ratio": InputSchema(
description="OTC heat curve ratio",
unit_of_measurement=UNIT_CELSIUS,
step=0.1,
message="OTC_CURVE_RATIO",
keep_updated=True,
message_data="f88",
range=(0, 127),
auto_min_value=AutoConfigure(message="OTC_CURVE_BOUNDS", message_data="u8_lb"),
auto_max_value=AutoConfigure(message="OTC_CURVE_BOUNDS", message_data="u8_hb"),
),
}
@dataclass
class SettingSchema(EntitySchema):
backing_type: str
validation_schema: cv.Schema
default_value: Any
order: Optional[int] = None
SETTINGS: dict[str, SettingSchema] = {
"controller_product_type": SettingSchema(
description="Controller product type",
message="VERSION_CONTROLLER",
keep_updated=False,
message_data="u8_hb",
backing_type="uint8_t",
validation_schema=cv.int_range(min=0, max=255),
default_value=0,
order=1,
),
"controller_product_version": SettingSchema(
description="Controller product version",
message="VERSION_CONTROLLER",
keep_updated=False,
message_data="u8_lb",
backing_type="uint8_t",
validation_schema=cv.int_range(min=0, max=255),
default_value=0,
order=1,
),
"opentherm_version_controller": SettingSchema(
description="Version of OpenTherm implemented by controller",
message="OT_VERSION_CONTROLLER",
keep_updated=False,
message_data="f88",
backing_type="float",
validation_schema=cv.positive_float,
default_value=0,
order=3,
),
"controller_configuration": SettingSchema(
description="Controller configuration",
message="CONTROLLER_CONFIG",
keep_updated=False,
message_data="u8_hb",
backing_type="uint8_t",
validation_schema=cv.int_range(min=0, max=255),
default_value=0,
order=5,
),
"controller_id": SettingSchema(
description="Controller ID code",
message="CONTROLLER_CONFIG",
keep_updated=False,
message_data="u8_lb",
backing_type="uint8_t",
validation_schema=cv.int_range(min=0, max=255),
default_value=0,
order=5,
),
}