# This file contains a schema for all supported sensors, binary sensors and
# inputs of the OpenTherm component.
from dataclasses import dataclass
from typing import Optional, TypeVar
from esphome.const import (
UNIT_CELSIUS,
UNIT_EMPTY,
UNIT_KILOWATT,
UNIT_MICROAMP,
UNIT_PERCENT,
UNIT_REVOLUTIONS_PER_MINUTE,
DEVICE_CLASS_CURRENT,
DEVICE_CLASS_EMPTY,
DEVICE_CLASS_PRESSURE,
DEVICE_CLASS_TEMPERATURE,
STATE_CLASS_MEASUREMENT,
STATE_CLASS_NONE,
STATE_CLASS_TOTAL_INCREASING,
)
@dataclass
class EntitySchema:
description: str
"""Description of the item, based on the OpenTherm spec"""
message: str
"""OpenTherm message id used to read or write the value"""
keep_updated: bool
"""Whether the value should be read or write repeatedly (True) or only during
the initialization phase (False)
"""
message_data: str
"""Instructions on how to interpret the data in the message
- flag8_[hb|lb]_[0-7]: data is a byte of single bit flags,
this flag is set in the high (hb) or low byte (lb),
at position 0 to 7
- u8_[hb|lb]: data is an unsigned 8-bit integer,
in the high (hb) or low byte (lb)
- s8_[hb|lb]: data is an signed 8-bit integer,
in the high (hb) or low byte (lb)
- f88: data is a signed fixed point value with
1 sign bit, 7 integer bits, 8 fractional bits
- u16: data is an unsigned 16-bit integer
- s16: data is a signed 16-bit integer
"""
TSchema = TypeVar("TSchema", bound=EntitySchema)
@dataclass
class SensorSchema(EntitySchema):
accuracy_decimals: int
state_class: str
unit_of_measurement: Optional[str] = None
icon: Optional[str] = None
device_class: Optional[str] = None
disabled_by_default: bool = False
SENSORS: dict[str, SensorSchema] = {
"rel_mod_level": SensorSchema(
description="Relative modulation level",
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=2,
icon="mdi:percent",
state_class=STATE_CLASS_MEASUREMENT,
message="MODULATION_LEVEL",
keep_updated=True,
message_data="f88",
),
"ch_pressure": SensorSchema(
description="Water pressure in CH circuit",
unit_of_measurement="bar",
accuracy_decimals=2,
device_class=DEVICE_CLASS_PRESSURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_WATER_PRESSURE",
keep_updated=True,
message_data="f88",
),
"dhw_flow_rate": SensorSchema(
description="Water flow rate in DHW circuit",
unit_of_measurement="l/min",
accuracy_decimals=2,
icon="mdi:waves-arrow-right",
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_FLOW_RATE",
keep_updated=True,
message_data="f88",
),
"t_boiler": SensorSchema(
description="Boiler water temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="FEED_TEMP",
keep_updated=True,
message_data="f88",
),
"t_dhw": SensorSchema(
description="DHW temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_TEMP",
keep_updated=True,
message_data="f88",
),
"t_outside": SensorSchema(
description="Outside temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="OUTSIDE_TEMP",
keep_updated=True,
message_data="f88",
),
"t_ret": SensorSchema(
description="Return water temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="RETURN_WATER_TEMP",
keep_updated=True,
message_data="f88",
),
"t_storage": SensorSchema(
description="Solar storage temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="SOLAR_STORE_TEMP",
keep_updated=True,
message_data="f88",
),
"t_collector": SensorSchema(
description="Solar collector temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="SOLAR_COLLECT_TEMP",
keep_updated=True,
message_data="s16",
),
"t_flow_ch2": SensorSchema(
description="Flow water temperature CH2 circuit",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="FEED_TEMP_CH2",
keep_updated=True,
message_data="f88",
),
"t_dhw2": SensorSchema(
description="Domestic hot water temperature 2",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW2_TEMP",
keep_updated=True,
message_data="f88",
),
"t_exhaust": SensorSchema(
description="Boiler exhaust temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="EXHAUST_TEMP",
keep_updated=True,
message_data="s16",
),
"fan_speed": SensorSchema(
description="Boiler fan speed",
unit_of_measurement=UNIT_REVOLUTIONS_PER_MINUTE,
accuracy_decimals=0,
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_MEASUREMENT,
message="FAN_SPEED",
keep_updated=True,
message_data="u16",
),
"flame_current": SensorSchema(
description="Boiler flame current",
unit_of_measurement=UNIT_MICROAMP,
accuracy_decimals=0,
device_class=DEVICE_CLASS_CURRENT,
state_class=STATE_CLASS_MEASUREMENT,
message="FLAME_CURRENT",
keep_updated=True,
message_data="f88",
),
"burner_starts": SensorSchema(
description="Number of starts burner",
accuracy_decimals=0,
icon="mdi:gas-burner",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="BURNER_STARTS",
keep_updated=True,
message_data="u16",
),
"ch_pump_starts": SensorSchema(
description="Number of starts CH pump",
accuracy_decimals=0,
icon="mdi:pump",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="CH_PUMP_STARTS",
keep_updated=True,
message_data="u16",
),
"dhw_pump_valve_starts": SensorSchema(
description="Number of starts DHW pump/valve",
accuracy_decimals=0,
icon="mdi:water-pump",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_PUMP_STARTS",
keep_updated=True,
message_data="u16",
),
"dhw_burner_starts": SensorSchema(
description="Number of starts burner during DHW mode",
accuracy_decimals=0,
icon="mdi:gas-burner",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_BURNER_STARTS",
keep_updated=True,
message_data="u16",
),
"burner_operation_hours": SensorSchema(
description="Number of hours that burner is in operation",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="BURNER_HOURS",
keep_updated=True,
message_data="u16",
),
"ch_pump_operation_hours": SensorSchema(
description="Number of hours that CH pump has been running",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="CH_PUMP_HOURS",
keep_updated=True,
message_data="u16",
),
"dhw_pump_valve_operation_hours": SensorSchema(
description="Number of hours that DHW pump has been running or DHW valve has been opened",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_PUMP_HOURS",
keep_updated=True,
message_data="u16",
),
"dhw_burner_operation_hours": SensorSchema(
description="Number of hours that burner is in operation during DHW mode",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_BURNER_HOURS",
keep_updated=True,
message_data="u16",
),
"t_dhw_set_ub": SensorSchema(
description="Upper bound for adjustment of DHW setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_BOUNDS",
keep_updated=False,
message_data="s8_hb",
),
"t_dhw_set_lb": SensorSchema(
description="Lower bound for adjustment of DHW setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_BOUNDS",
keep_updated=False,
message_data="s8_lb",
),
"max_t_set_ub": SensorSchema(
description="Upper bound for adjustment of max CH setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_BOUNDS",
keep_updated=False,
message_data="s8_hb",
),
"max_t_set_lb": SensorSchema(
description="Lower bound for adjustment of max CH setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_BOUNDS",
keep_updated=False,
message_data="s8_lb",
),
"t_dhw_set": SensorSchema(
description="Domestic hot water temperature setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_SETPOINT",
keep_updated=True,
message_data="f88",
),
"max_t_set": SensorSchema(
description="Maximum allowable CH water setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="MAX_CH_SETPOINT",
keep_updated=True,
message_data="f88",
),
"oem_fault_code": SensorSchema(
description="OEM fault code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
message="FAULT_FLAGS",
keep_updated=True,
message_data="u8_lb",
),
"oem_diagnostic_code": SensorSchema(
description="OEM diagnostic code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
message="OEM_DIAGNOSTIC",
keep_updated=True,
message_data="u16",
),
"max_capacity": SensorSchema(
description="Maximum boiler capacity (KW)",
unit_of_measurement=UNIT_KILOWATT,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
disabled_by_default=True,
message="MAX_BOILER_CAPACITY",
keep_updated=False,
message_data="u8_hb",
),
"min_mod_level": SensorSchema(
description="Minimum modulation level",
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=0,
icon="mdi:percent",
disabled_by_default=True,
state_class=STATE_CLASS_MEASUREMENT,
message="MAX_BOILER_CAPACITY",
keep_updated=False,
message_data="u8_lb",
),
"opentherm_version_device": SensorSchema(
description="Version of OpenTherm implemented by device",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OT_VERSION_DEVICE",
keep_updated=False,
message_data="f88",
),
"device_type": SensorSchema(
description="Device product type",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="VERSION_DEVICE",
keep_updated=False,
message_data="u8_hb",
),
"device_version": SensorSchema(
description="Device product version",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="VERSION_DEVICE",
keep_updated=False,
message_data="u8_lb",
),
"device_id": SensorSchema(
description="Device ID code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="DEVICE_CONFIG",
keep_updated=False,
message_data="u8_lb",
),
"otc_hc_ratio_ub": SensorSchema(
description="OTC heat curve ratio upper bound",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OTC_CURVE_BOUNDS",
keep_updated=False,
message_data="u8_hb",
),
"otc_hc_ratio_lb": SensorSchema(
description="OTC heat curve ratio lower bound",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OTC_CURVE_BOUNDS",
keep_updated=False,
message_data="u8_lb",
),
}