mirror of
https://github.com/esphome/esphome.git
synced 2025-02-22 12:58:15 +00:00
261 lines
9.0 KiB
Python
261 lines
9.0 KiB
Python
import esphome.codegen as cg
|
|
import esphome.config_validation as cv
|
|
from esphome.components import sensor, uart
|
|
|
|
from esphome.const import (
|
|
CONF_FORMALDEHYDE,
|
|
CONF_HUMIDITY,
|
|
CONF_ID,
|
|
CONF_PM_10_0,
|
|
CONF_PM_1_0,
|
|
CONF_PM_2_5,
|
|
CONF_PM_10_0_STD,
|
|
CONF_PM_1_0_STD,
|
|
CONF_PM_2_5_STD,
|
|
CONF_PM_0_3UM,
|
|
CONF_PM_0_5UM,
|
|
CONF_PM_1_0UM,
|
|
CONF_PM_2_5UM,
|
|
CONF_PM_5_0UM,
|
|
CONF_PM_10_0UM,
|
|
CONF_UPDATE_INTERVAL,
|
|
CONF_TEMPERATURE,
|
|
CONF_TYPE,
|
|
DEVICE_CLASS_PM1,
|
|
DEVICE_CLASS_PM10,
|
|
DEVICE_CLASS_PM25,
|
|
DEVICE_CLASS_HUMIDITY,
|
|
DEVICE_CLASS_TEMPERATURE,
|
|
ICON_CHEMICAL_WEAPON,
|
|
STATE_CLASS_MEASUREMENT,
|
|
UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
UNIT_CELSIUS,
|
|
UNIT_COUNT_DECILITRE,
|
|
UNIT_PERCENT,
|
|
)
|
|
|
|
DEPENDENCIES = ["uart"]
|
|
|
|
pmsx003_ns = cg.esphome_ns.namespace("pmsx003")
|
|
PMSX003Component = pmsx003_ns.class_("PMSX003Component", uart.UARTDevice, cg.Component)
|
|
PMSX003Sensor = pmsx003_ns.class_("PMSX003Sensor", sensor.Sensor)
|
|
|
|
TYPE_PMSX003 = "PMSX003"
|
|
TYPE_PMS5003T = "PMS5003T"
|
|
TYPE_PMS5003ST = "PMS5003ST"
|
|
TYPE_PMS5003S = "PMS5003S"
|
|
|
|
PMSX003Type = pmsx003_ns.enum("PMSX003Type")
|
|
|
|
PMSX003_TYPES = {
|
|
TYPE_PMSX003: PMSX003Type.PMSX003_TYPE_X003,
|
|
TYPE_PMS5003T: PMSX003Type.PMSX003_TYPE_5003T,
|
|
TYPE_PMS5003ST: PMSX003Type.PMSX003_TYPE_5003ST,
|
|
TYPE_PMS5003S: PMSX003Type.PMSX003_TYPE_5003S,
|
|
}
|
|
|
|
SENSORS_TO_TYPE = {
|
|
CONF_PM_1_0: [TYPE_PMSX003, TYPE_PMS5003ST, TYPE_PMS5003S],
|
|
CONF_PM_2_5: [TYPE_PMSX003, TYPE_PMS5003T, TYPE_PMS5003ST, TYPE_PMS5003S],
|
|
CONF_PM_10_0: [TYPE_PMSX003, TYPE_PMS5003ST, TYPE_PMS5003S],
|
|
CONF_TEMPERATURE: [TYPE_PMS5003T, TYPE_PMS5003ST],
|
|
CONF_HUMIDITY: [TYPE_PMS5003T, TYPE_PMS5003ST],
|
|
CONF_FORMALDEHYDE: [TYPE_PMS5003ST, TYPE_PMS5003S],
|
|
}
|
|
|
|
|
|
def validate_pmsx003_sensors(value):
|
|
for key, types in SENSORS_TO_TYPE.items():
|
|
if key in value and value[CONF_TYPE] not in types:
|
|
raise cv.Invalid(f"{value[CONF_TYPE]} does not have {key} sensor!")
|
|
return value
|
|
|
|
|
|
def validate_update_interval(value):
|
|
value = cv.positive_time_period_milliseconds(value)
|
|
if value == cv.time_period("0s"):
|
|
return value
|
|
if value < cv.time_period("30s"):
|
|
raise cv.Invalid(
|
|
"Update interval must be greater than or equal to 30 seconds if set."
|
|
)
|
|
return value
|
|
|
|
|
|
CONFIG_SCHEMA = (
|
|
cv.Schema(
|
|
{
|
|
cv.GenerateID(): cv.declare_id(PMSX003Component),
|
|
cv.Required(CONF_TYPE): cv.enum(PMSX003_TYPES, upper=True),
|
|
cv.Optional(CONF_PM_1_0_STD): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_PM1,
|
|
),
|
|
cv.Optional(CONF_PM_2_5_STD): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_PM25,
|
|
),
|
|
cv.Optional(CONF_PM_10_0_STD): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_PM10,
|
|
),
|
|
cv.Optional(CONF_PM_1_0): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_PM_2_5): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_PM_10_0): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_PM_0_3UM): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_COUNT_DECILITRE,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
),
|
|
cv.Optional(CONF_PM_0_5UM): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_COUNT_DECILITRE,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
),
|
|
cv.Optional(CONF_PM_1_0UM): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_COUNT_DECILITRE,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
),
|
|
cv.Optional(CONF_PM_2_5UM): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_COUNT_DECILITRE,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
),
|
|
cv.Optional(CONF_PM_5_0UM): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_COUNT_DECILITRE,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
),
|
|
cv.Optional(CONF_PM_10_0UM): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_COUNT_DECILITRE,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
),
|
|
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=1,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_PERCENT,
|
|
accuracy_decimals=1,
|
|
device_class=DEVICE_CLASS_HUMIDITY,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_FORMALDEHYDE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
icon=ICON_CHEMICAL_WEAPON,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_UPDATE_INTERVAL, default="0s"): validate_update_interval,
|
|
}
|
|
)
|
|
.extend(cv.COMPONENT_SCHEMA)
|
|
.extend(uart.UART_DEVICE_SCHEMA)
|
|
)
|
|
|
|
|
|
def final_validate(config):
|
|
require_tx = config[CONF_UPDATE_INTERVAL] > cv.time_period("0s")
|
|
schema = uart.final_validate_device_schema(
|
|
"pmsx003", baud_rate=9600, require_rx=True, require_tx=require_tx
|
|
)
|
|
schema(config)
|
|
|
|
|
|
FINAL_VALIDATE_SCHEMA = final_validate
|
|
|
|
|
|
async def to_code(config):
|
|
var = cg.new_Pvariable(config[CONF_ID])
|
|
await cg.register_component(var, config)
|
|
await uart.register_uart_device(var, config)
|
|
|
|
cg.add(var.set_type(config[CONF_TYPE]))
|
|
|
|
if CONF_PM_1_0_STD in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_1_0_STD])
|
|
cg.add(var.set_pm_1_0_std_sensor(sens))
|
|
|
|
if CONF_PM_2_5_STD in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_2_5_STD])
|
|
cg.add(var.set_pm_2_5_std_sensor(sens))
|
|
|
|
if CONF_PM_10_0_STD in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_10_0_STD])
|
|
cg.add(var.set_pm_10_0_std_sensor(sens))
|
|
|
|
if CONF_PM_1_0 in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_1_0])
|
|
cg.add(var.set_pm_1_0_sensor(sens))
|
|
|
|
if CONF_PM_2_5 in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_2_5])
|
|
cg.add(var.set_pm_2_5_sensor(sens))
|
|
|
|
if CONF_PM_10_0 in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_10_0])
|
|
cg.add(var.set_pm_10_0_sensor(sens))
|
|
|
|
if CONF_PM_0_3UM in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_0_3UM])
|
|
cg.add(var.set_pm_particles_03um_sensor(sens))
|
|
|
|
if CONF_PM_0_5UM in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_0_5UM])
|
|
cg.add(var.set_pm_particles_05um_sensor(sens))
|
|
|
|
if CONF_PM_1_0UM in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_1_0UM])
|
|
cg.add(var.set_pm_particles_10um_sensor(sens))
|
|
|
|
if CONF_PM_2_5UM in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_2_5UM])
|
|
cg.add(var.set_pm_particles_25um_sensor(sens))
|
|
|
|
if CONF_PM_5_0UM in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_5_0UM])
|
|
cg.add(var.set_pm_particles_50um_sensor(sens))
|
|
|
|
if CONF_PM_10_0UM in config:
|
|
sens = await sensor.new_sensor(config[CONF_PM_10_0UM])
|
|
cg.add(var.set_pm_particles_100um_sensor(sens))
|
|
|
|
if CONF_TEMPERATURE in config:
|
|
sens = await sensor.new_sensor(config[CONF_TEMPERATURE])
|
|
cg.add(var.set_temperature_sensor(sens))
|
|
|
|
if CONF_HUMIDITY in config:
|
|
sens = await sensor.new_sensor(config[CONF_HUMIDITY])
|
|
cg.add(var.set_humidity_sensor(sens))
|
|
|
|
if CONF_FORMALDEHYDE in config:
|
|
sens = await sensor.new_sensor(config[CONF_FORMALDEHYDE])
|
|
cg.add(var.set_formaldehyde_sensor(sens))
|
|
|
|
cg.add(var.set_update_interval(config[CONF_UPDATE_INTERVAL]))
|