mirror of
https://github.com/esphome/esphome.git
synced 2025-01-22 22:04:06 +00:00
7f895abc24
* Add support for Sensirion SPS30 Particulate Matter sensors * Remove blocking of the main thread on initialization; Improve wording on the debug messages; Add robustness in re-initialization of reconnected or replaced sensors; * Fix code formatting; Co-authored-by: Nad <valordk@github>
83 lines
3.7 KiB
Python
83 lines
3.7 KiB
Python
import esphome.codegen as cg
|
|
import esphome.config_validation as cv
|
|
from esphome.components import i2c, sensor
|
|
from esphome.const import CONF_ID, CONF_PM_1_0, CONF_PM_2_5, CONF_PM_4_0, CONF_PM_10_0, \
|
|
CONF_PMC_0_5, CONF_PMC_1_0, CONF_PMC_2_5, CONF_PMC_4_0, CONF_PMC_10_0, CONF_PM_SIZE, \
|
|
UNIT_MICROGRAMS_PER_CUBIC_METER, UNIT_COUNTS_PER_CUBIC_METER, UNIT_MICROMETER, \
|
|
ICON_CHEMICAL_WEAPON, ICON_COUNTER, ICON_RULER
|
|
|
|
DEPENDENCIES = ['i2c']
|
|
|
|
sps30_ns = cg.esphome_ns.namespace('sps30')
|
|
SPS30Component = sps30_ns.class_('SPS30Component', cg.PollingComponent, i2c.I2CDevice)
|
|
|
|
CONFIG_SCHEMA = cv.Schema({
|
|
cv.GenerateID(): cv.declare_id(SPS30Component),
|
|
cv.Optional(CONF_PM_1_0): sensor.sensor_schema(UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
ICON_CHEMICAL_WEAPON, 2),
|
|
cv.Optional(CONF_PM_2_5): sensor.sensor_schema(UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
ICON_CHEMICAL_WEAPON, 2),
|
|
cv.Optional(CONF_PM_4_0): sensor.sensor_schema(UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
ICON_CHEMICAL_WEAPON, 2),
|
|
cv.Optional(CONF_PM_10_0): sensor.sensor_schema(UNIT_MICROGRAMS_PER_CUBIC_METER,
|
|
ICON_CHEMICAL_WEAPON, 2),
|
|
cv.Optional(CONF_PMC_0_5): sensor.sensor_schema(UNIT_COUNTS_PER_CUBIC_METER,
|
|
ICON_COUNTER, 2),
|
|
cv.Optional(CONF_PMC_1_0): sensor.sensor_schema(UNIT_COUNTS_PER_CUBIC_METER,
|
|
ICON_COUNTER, 2),
|
|
cv.Optional(CONF_PMC_2_5): sensor.sensor_schema(UNIT_COUNTS_PER_CUBIC_METER,
|
|
ICON_COUNTER, 2),
|
|
cv.Optional(CONF_PMC_4_0): sensor.sensor_schema(UNIT_COUNTS_PER_CUBIC_METER,
|
|
ICON_COUNTER, 2),
|
|
cv.Optional(CONF_PMC_10_0): sensor.sensor_schema(UNIT_COUNTS_PER_CUBIC_METER,
|
|
ICON_COUNTER, 2),
|
|
cv.Optional(CONF_PM_SIZE): sensor.sensor_schema(UNIT_MICROMETER,
|
|
ICON_RULER, 0),
|
|
}).extend(cv.polling_component_schema('60s')).extend(i2c.i2c_device_schema(0x69))
|
|
|
|
|
|
def to_code(config):
|
|
var = cg.new_Pvariable(config[CONF_ID])
|
|
yield cg.register_component(var, config)
|
|
yield i2c.register_i2c_device(var, config)
|
|
|
|
if CONF_PM_1_0 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PM_1_0])
|
|
cg.add(var.set_pm_1_0_sensor(sens))
|
|
|
|
if CONF_PM_2_5 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PM_2_5])
|
|
cg.add(var.set_pm_2_5_sensor(sens))
|
|
|
|
if CONF_PM_4_0 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PM_4_0])
|
|
cg.add(var.set_pm_4_0_sensor(sens))
|
|
|
|
if CONF_PM_10_0 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PM_10_0])
|
|
cg.add(var.set_pm_10_0_sensor(sens))
|
|
|
|
if CONF_PMC_0_5 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PMC_0_5])
|
|
cg.add(var.set_pmc_0_5_sensor(sens))
|
|
|
|
if CONF_PMC_1_0 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PMC_1_0])
|
|
cg.add(var.set_pmc_1_0_sensor(sens))
|
|
|
|
if CONF_PMC_2_5 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PMC_2_5])
|
|
cg.add(var.set_pmc_2_5_sensor(sens))
|
|
|
|
if CONF_PMC_4_0 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PMC_4_0])
|
|
cg.add(var.set_pmc_4_0_sensor(sens))
|
|
|
|
if CONF_PMC_10_0 in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PMC_10_0])
|
|
cg.add(var.set_pmc_10_0_sensor(sens))
|
|
|
|
if CONF_PM_SIZE in config:
|
|
sens = yield sensor.new_sensor(config[CONF_PM_SIZE])
|
|
cg.add(var.set_pm_size_sensor(sens))
|