import esphome.codegen as cg import esphome.config_validation as cv from esphome import pins from esphome.components import sensor from esphome.const import ( CONF_CHANGE_MODE_EVERY, CONF_INITIAL_MODE, CONF_CURRENT, CONF_CURRENT_RESISTOR, CONF_ID, CONF_POWER, CONF_ENERGY, CONF_SEL_PIN, CONF_MODEL, CONF_VOLTAGE, CONF_VOLTAGE_DIVIDER, DEVICE_CLASS_CURRENT, DEVICE_CLASS_ENERGY, DEVICE_CLASS_POWER, DEVICE_CLASS_VOLTAGE, STATE_CLASS_MEASUREMENT, STATE_CLASS_TOTAL_INCREASING, UNIT_VOLT, UNIT_AMPERE, UNIT_WATT, UNIT_WATT_HOURS, ) AUTO_LOAD = ["pulse_counter"] hlw8012_ns = cg.esphome_ns.namespace("hlw8012") HLW8012Component = hlw8012_ns.class_("HLW8012Component", cg.PollingComponent) HLW8012InitialMode = hlw8012_ns.enum("HLW8012InitialMode") HLW8012SensorModels = hlw8012_ns.enum("HLW8012SensorModels") INITIAL_MODES = { CONF_CURRENT: HLW8012InitialMode.HLW8012_INITIAL_MODE_CURRENT, CONF_VOLTAGE: HLW8012InitialMode.HLW8012_INITIAL_MODE_VOLTAGE, } MODELS = { "HLW8012": HLW8012SensorModels.HLW8012_SENSOR_MODEL_HLW8012, "CSE7759": HLW8012SensorModels.HLW8012_SENSOR_MODEL_CSE7759, "BL0937": HLW8012SensorModels.HLW8012_SENSOR_MODEL_BL0937, } CONF_CF1_PIN = "cf1_pin" CONF_CF_PIN = "cf_pin" CONFIG_SCHEMA = cv.Schema( { cv.GenerateID(): cv.declare_id(HLW8012Component), cv.Required(CONF_SEL_PIN): pins.gpio_output_pin_schema, cv.Required(CONF_CF_PIN): cv.All( pins.internal_gpio_input_pullup_pin_schema, pins.validate_has_interrupt ), cv.Required(CONF_CF1_PIN): cv.All( pins.internal_gpio_input_pullup_pin_schema, pins.validate_has_interrupt ), cv.Optional(CONF_VOLTAGE): sensor.sensor_schema( unit_of_measurement=UNIT_VOLT, accuracy_decimals=1, device_class=DEVICE_CLASS_VOLTAGE, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_CURRENT): sensor.sensor_schema( unit_of_measurement=UNIT_AMPERE, accuracy_decimals=2, device_class=DEVICE_CLASS_CURRENT, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_POWER): sensor.sensor_schema( unit_of_measurement=UNIT_WATT, accuracy_decimals=1, device_class=DEVICE_CLASS_POWER, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_ENERGY): sensor.sensor_schema( unit_of_measurement=UNIT_WATT_HOURS, accuracy_decimals=1, device_class=DEVICE_CLASS_ENERGY, state_class=STATE_CLASS_TOTAL_INCREASING, ), cv.Optional(CONF_CURRENT_RESISTOR, default=0.001): cv.resistance, cv.Optional(CONF_VOLTAGE_DIVIDER, default=2351): cv.positive_float, cv.Optional(CONF_MODEL, default="HLW8012"): cv.enum(MODELS, upper=True), cv.Optional(CONF_CHANGE_MODE_EVERY, default=8): cv.All( cv.uint32_t, cv.Range(min=1) ), cv.Optional(CONF_INITIAL_MODE, default=CONF_VOLTAGE): cv.one_of( *INITIAL_MODES, lower=True ), } ).extend(cv.polling_component_schema("60s")) async def to_code(config): var = cg.new_Pvariable(config[CONF_ID]) await cg.register_component(var, config) sel = await cg.gpio_pin_expression(config[CONF_SEL_PIN]) cg.add(var.set_sel_pin(sel)) cf = await cg.gpio_pin_expression(config[CONF_CF_PIN]) cg.add(var.set_cf_pin(cf)) cf1 = await cg.gpio_pin_expression(config[CONF_CF1_PIN]) cg.add(var.set_cf1_pin(cf1)) if CONF_VOLTAGE in config: sens = await sensor.new_sensor(config[CONF_VOLTAGE]) cg.add(var.set_voltage_sensor(sens)) if CONF_CURRENT in config: sens = await sensor.new_sensor(config[CONF_CURRENT]) cg.add(var.set_current_sensor(sens)) if CONF_POWER in config: sens = await sensor.new_sensor(config[CONF_POWER]) cg.add(var.set_power_sensor(sens)) if CONF_ENERGY in config: sens = await sensor.new_sensor(config[CONF_ENERGY]) cg.add(var.set_energy_sensor(sens)) cg.add(var.set_current_resistor(config[CONF_CURRENT_RESISTOR])) cg.add(var.set_voltage_divider(config[CONF_VOLTAGE_DIVIDER])) cg.add(var.set_change_mode_every(config[CONF_CHANGE_MODE_EVERY])) cg.add(var.set_initial_mode(INITIAL_MODES[config[CONF_INITIAL_MODE]])) cg.add(var.set_sensor_model(config[CONF_MODEL]))