1
0
mirror of https://github.com/esphome/esphome.git synced 2025-10-29 22:24:26 +00:00

Remove last_reset_type and convert all those sensors to TOTAL_INCREASING (#2233)

This commit is contained in:
Jesse Hills
2021-09-06 08:30:47 +12:00
committed by GitHub
parent f9b0666adf
commit ff6bed54c6
22 changed files with 60 additions and 191 deletions

View File

@@ -9,9 +9,9 @@ from esphome.const import (
DEVICE_CLASS_POWER,
DEVICE_CLASS_VOLTAGE,
ICON_EMPTY,
LAST_RESET_TYPE_NEVER,
STATE_CLASS_MEASUREMENT,
STATE_CLASS_NONE,
STATE_CLASS_TOTAL_INCREASING,
UNIT_AMPERE,
UNIT_EMPTY,
UNIT_VOLT,
@@ -26,52 +26,22 @@ CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(CONF_DSMR_ID): cv.use_id(Dsmr),
cv.Optional("energy_delivered_lux"): sensor.sensor_schema(
"kWh",
ICON_EMPTY,
3,
DEVICE_CLASS_ENERGY,
STATE_CLASS_MEASUREMENT,
LAST_RESET_TYPE_NEVER,
"kWh", ICON_EMPTY, 3, DEVICE_CLASS_ENERGY, STATE_CLASS_TOTAL_INCREASING
),
cv.Optional("energy_delivered_tariff1"): sensor.sensor_schema(
"kWh",
ICON_EMPTY,
3,
DEVICE_CLASS_ENERGY,
STATE_CLASS_MEASUREMENT,
LAST_RESET_TYPE_NEVER,
"kWh", ICON_EMPTY, 3, DEVICE_CLASS_ENERGY, STATE_CLASS_TOTAL_INCREASING
),
cv.Optional("energy_delivered_tariff2"): sensor.sensor_schema(
"kWh",
ICON_EMPTY,
3,
DEVICE_CLASS_ENERGY,
STATE_CLASS_MEASUREMENT,
LAST_RESET_TYPE_NEVER,
"kWh", ICON_EMPTY, 3, DEVICE_CLASS_ENERGY, STATE_CLASS_TOTAL_INCREASING
),
cv.Optional("energy_returned_lux"): sensor.sensor_schema(
"kWh",
ICON_EMPTY,
3,
DEVICE_CLASS_ENERGY,
STATE_CLASS_MEASUREMENT,
LAST_RESET_TYPE_NEVER,
"kWh", ICON_EMPTY, 3, DEVICE_CLASS_ENERGY, STATE_CLASS_TOTAL_INCREASING
),
cv.Optional("energy_returned_tariff1"): sensor.sensor_schema(
"kWh",
ICON_EMPTY,
3,
DEVICE_CLASS_ENERGY,
STATE_CLASS_MEASUREMENT,
LAST_RESET_TYPE_NEVER,
"kWh", ICON_EMPTY, 3, DEVICE_CLASS_ENERGY, STATE_CLASS_TOTAL_INCREASING
),
cv.Optional("energy_returned_tariff2"): sensor.sensor_schema(
"kWh",
ICON_EMPTY,
3,
DEVICE_CLASS_ENERGY,
STATE_CLASS_MEASUREMENT,
LAST_RESET_TYPE_NEVER,
"kWh", ICON_EMPTY, 3, DEVICE_CLASS_ENERGY, STATE_CLASS_TOTAL_INCREASING
),
cv.Optional("total_imported_energy"): sensor.sensor_schema(
"kvarh", ICON_EMPTY, 3, DEVICE_CLASS_ENERGY, STATE_CLASS_NONE
@@ -176,20 +146,10 @@ CONFIG_SCHEMA = cv.Schema(
UNIT_VOLT, ICON_EMPTY, 1, DEVICE_CLASS_VOLTAGE, STATE_CLASS_NONE
),
cv.Optional("gas_delivered"): sensor.sensor_schema(
"",
ICON_EMPTY,
3,
DEVICE_CLASS_GAS,
STATE_CLASS_MEASUREMENT,
LAST_RESET_TYPE_NEVER,
"", ICON_EMPTY, 3, DEVICE_CLASS_GAS, STATE_CLASS_TOTAL_INCREASING
),
cv.Optional("gas_delivered_be"): sensor.sensor_schema(
"",
ICON_EMPTY,
3,
DEVICE_CLASS_GAS,
STATE_CLASS_MEASUREMENT,
LAST_RESET_TYPE_NEVER,
"", ICON_EMPTY, 3, DEVICE_CLASS_GAS, STATE_CLASS_TOTAL_INCREASING
),
}
).extend(cv.COMPONENT_SCHEMA)