1
0
mirror of https://github.com/esphome/esphome.git synced 2025-11-15 14:25:45 +00:00

BME680 BSEC: Allow sample rate overrides for T/P/H sensors (#1710)

This commit is contained in:
Trevor North
2021-05-23 21:27:19 +01:00
committed by GitHub
parent 063d9c47a4
commit cccb1a2c9e
5 changed files with 141 additions and 98 deletions

View File

@@ -22,7 +22,12 @@ from esphome.const import (
ICON_WATER_PERCENT,
)
from esphome.core import coroutine
from . import BME680BSECComponent, CONF_BME680_BSEC_ID
from . import (
BME680BSECComponent,
CONF_BME680_BSEC_ID,
CONF_SAMPLE_RATE,
SAMPLE_RATE_OPTIONS,
)
DEPENDENCIES = ["bme680_bsec"]
@@ -34,28 +39,34 @@ UNIT_IAQ = "IAQ"
ICON_ACCURACY = "mdi:checkbox-marked-circle-outline"
ICON_TEST_TUBE = "mdi:test-tube"
TYPES = {
CONF_TEMPERATURE: "set_temperature_sensor",
CONF_PRESSURE: "set_pressure_sensor",
CONF_HUMIDITY: "set_humidity_sensor",
CONF_GAS_RESISTANCE: "set_gas_resistance_sensor",
CONF_IAQ: "set_iaq_sensor",
CONF_IAQ_ACCURACY: "set_iaq_accuracy_sensor",
CONF_CO2_EQUIVALENT: "set_co2_equivalent_sensor",
CONF_BREATH_VOC_EQUIVALENT: "set_breath_voc_equivalent_sensor",
}
TYPES = [
CONF_TEMPERATURE,
CONF_PRESSURE,
CONF_HUMIDITY,
CONF_GAS_RESISTANCE,
CONF_IAQ,
CONF_IAQ_ACCURACY,
CONF_CO2_EQUIVALENT,
CONF_BREATH_VOC_EQUIVALENT,
]
CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(CONF_BME680_BSEC_ID): cv.use_id(BME680BSECComponent),
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
UNIT_CELSIUS, ICON_THERMOMETER, 1, DEVICE_CLASS_TEMPERATURE
).extend(
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
),
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
UNIT_HECTOPASCAL, ICON_GAUGE, 1, DEVICE_CLASS_PRESSURE
).extend(
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
),
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
UNIT_PERCENT, ICON_WATER_PERCENT, 1, DEVICE_CLASS_HUMIDITY
).extend(
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
),
cv.Optional(CONF_GAS_RESISTANCE): sensor.sensor_schema(
UNIT_OHM, ICON_GAS_CYLINDER, 0, DEVICE_CLASS_EMPTY
@@ -77,15 +88,16 @@ CONFIG_SCHEMA = cv.Schema(
@coroutine
def setup_conf(config, key, hub, funcName):
def setup_conf(config, key, hub):
if key in config:
conf = config[key]
var = yield sensor.new_sensor(conf)
func = getattr(hub, funcName)
cg.add(func(var))
sens = yield sensor.new_sensor(conf)
cg.add(getattr(hub, f"set_{key}_sensor")(sens))
if CONF_SAMPLE_RATE in conf:
cg.add(getattr(hub, f"set_{key}_sample_rate")(conf[CONF_SAMPLE_RATE]))
def to_code(config):
hub = yield cg.get_variable(config[CONF_BME680_BSEC_ID])
for key, funcName in TYPES.items():
yield setup_conf(config, key, hub, funcName)
for key in TYPES: