1
0
mirror of https://github.com/esphome/esphome.git synced 2025-09-14 17:22:20 +01:00

Remove power and energy from sensors that are not true power (#2628)

This commit is contained in:
Jesse Hills
2021-10-26 21:55:20 +13:00
committed by GitHub
parent 87328686a0
commit a01f5f5cf1
5 changed files with 11 additions and 25 deletions

View File

@@ -64,13 +64,11 @@ PHASE_SENSORS = {
CONF_APPARENT_POWER: sensor.sensor_schema(
unit_of_measurement=UNIT_VOLT_AMPS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_REACTIVE_POWER: sensor.sensor_schema(
unit_of_measurement=UNIT_VOLT_AMPS_REACTIVE,
accuracy_decimals=2,
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_POWER_FACTOR: sensor.sensor_schema(
@@ -115,13 +113,11 @@ CONFIG_SCHEMA = (
cv.Optional(CONF_IMPORT_REACTIVE_ENERGY): sensor.sensor_schema(
unit_of_measurement=UNIT_KILOVOLT_AMPS_REACTIVE_HOURS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_ENERGY,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
cv.Optional(CONF_EXPORT_REACTIVE_ENERGY): sensor.sensor_schema(
unit_of_measurement=UNIT_KILOVOLT_AMPS_REACTIVE_HOURS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_ENERGY,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
}