1
0
mirror of https://github.com/esphome/esphome.git synced 2025-11-03 16:41:50 +00:00

YAML linting (#3779)

This commit is contained in:
Jesse Hills
2022-09-06 15:48:01 +12:00
committed by GitHub
parent c317422ed7
commit 89fd367297
27 changed files with 1039 additions and 933 deletions

View File

@@ -1,3 +1,4 @@
---
esphome:
name: test5
build_path: build/test5
@@ -60,8 +61,10 @@ mqtt:
topic: testing/sensor/testing_sensor/state
qos: 0
then:
# yamllint disable rule:line-length
- lambda: |-
ESP_LOGD("Mqtt Test","testing/sensor/testing_sensor/state=[%s]",x.c_str());
ESP_LOGD("Mqtt Test", "testing/sensor/testing_sensor/state=[%s]", x.c_str());
# yamllint enable rule:line-length
binary_sensor:
- platform: gpio
@@ -74,8 +77,8 @@ binary_sensor:
id: modbus_binsensortest
register_type: read
address: 0x3200
bitmask: 0x80 #(bit 8)
lambda: !lambda "{ return x ;}"
bitmask: 0x80 # (bit 8)
lambda: "return x;"
tlc5947:
data_pin: GPIO12
@@ -108,8 +111,8 @@ demo:
esp32_ble:
esp32_ble_server:
manufacturer: "ESPHome"
model: "Test5"
manufacturer: ESPHome
model: Test5
esp32_improv:
authorizer: io0_button
@@ -128,12 +131,12 @@ number:
mode: slider
on_value:
- logger.log:
format: "Number changed to %f"
args: ["x"]
format: Number changed to %f
args: [x]
set_action:
- logger.log:
format: "Template Number set to %f"
args: ["x"]
format: Template Number set to %f
args: [x]
- number.set:
id: template_number_id
value: 50
@@ -163,10 +166,10 @@ number:
- id: modbus_numbertest
platform: modbus_controller
modbus_controller_id: modbus_controller_test
name: "ModbusNumber"
name: ModbusNumber
address: 0x9002
value_type: U_WORD
lambda: "return x * 1.0; "
lambda: "return x * 1.0;"
write_lambda: |-
return x * 1.0 ;
multiply: 1.0
@@ -180,11 +183,11 @@ select:
restore_value: true
on_value:
- logger.log:
format: "Select changed to %s (index %d)"
format: Select changed to %s (index %d)"
args: ["x.c_str()", "i"]
set_action:
- logger.log:
format: "Template Select set to %s"
format: Template Select set to %s
args: ["x.c_str()"]
- select.set:
id: template_select_id
@@ -216,7 +219,7 @@ select:
- three
- platform: modbus_controller
name: "Modbus Select Register 1000"
name: Modbus Select Register 1000
address: 1000
value_type: U_WORD
optionsmap:
@@ -228,41 +231,41 @@ select:
sensor:
- platform: selec_meter
total_active_energy:
name: "SelecEM2M Total Active Energy"
name: SelecEM2M Total Active Energy
import_active_energy:
name: "SelecEM2M Import Active Energy"
name: SelecEM2M Import Active Energy
export_active_energy:
name: "SelecEM2M Export Active Energy"
name: SelecEM2M Export Active Energy
total_reactive_energy:
name: "SelecEM2M Total Reactive Energy"
name: SelecEM2M Total Reactive Energy
import_reactive_energy:
name: "SelecEM2M Import Reactive Energy"
name: SelecEM2M Import Reactive Energy
export_reactive_energy:
name: "SelecEM2M Export Reactive Energy"
name: SelecEM2M Export Reactive Energy
apparent_energy:
name: "SelecEM2M Apparent Energy"
name: SelecEM2M Apparent Energy
active_power:
name: "SelecEM2M Active Power"
name: SelecEM2M Active Power
reactive_power:
name: "SelecEM2M Reactive Power"
name: SelecEM2M Reactive Power
apparent_power:
name: "SelecEM2M Apparent Power"
name: SelecEM2M Apparent Power
voltage:
name: "SelecEM2M Voltage"
name: SelecEM2M Voltage
current:
name: "SelecEM2M Current"
name: SelecEM2M Current
power_factor:
name: "SelecEM2M Power Factor"
name: SelecEM2M Power Factor
frequency:
name: "SelecEM2M Frequency"
name: SelecEM2M Frequency
maximum_demand_active_power:
name: "SelecEM2M Maximum Demand Active Power"
name: SelecEM2M Maximum Demand Active Power
disabled_by_default: true
maximum_demand_reactive_power:
name: "SelecEM2M Maximum Demand Reactive Power"
name: SelecEM2M Maximum Demand Reactive Power
disabled_by_default: true
maximum_demand_apparent_power:
name: "SelecEM2M Maximum Demand Apparent Power"
name: SelecEM2M Maximum Demand Apparent Power
disabled_by_default: true
- id: modbus_sensortest
@@ -279,41 +282,41 @@ sensor:
- platform: bmp3xx
temperature:
name: "BMP Temperature"
name: BMP Temperature
oversampling: 16x
pressure:
name: "BMP Pressure"
name: BMP Pressure
address: 0x77
iir_filter: 2X
- platform: sen5x
id: sen54
temperature:
name: "Temperature"
name: Temperature
accuracy_decimals: 1
humidity:
name: "Humidity"
name: Humidity
accuracy_decimals: 0
pm_1_0:
name: " PM <1µm Weight concentration"
name: PM <1µm Weight concentration
id: pm_1_0
accuracy_decimals: 1
pm_2_5:
name: " PM <2.5µm Weight concentration"
name: PM <2.5µm Weight concentration
id: pm_2_5
accuracy_decimals: 1
pm_4_0:
name: " PM <4µm Weight concentration"
name: PM <4µm Weight concentration
id: pm_4_0
accuracy_decimals: 1
pm_10_0:
name: " PM <10µm Weight concentration"
name: PM <10µm Weight concentration
id: pm_10_0
accuracy_decimals: 1
nox:
name: "NOx"
name: NOx
voc:
name: "VOC"
name: VOC
algorithm_tuning:
index_offset: 100
learning_time_offset_hours: 12
@@ -332,9 +335,9 @@ sensor:
- platform: mcp9600
thermocouple_type: K
hot_junction:
name: "Thermocouple Temperature"
name: Thermocouple Temperature
cold_junction:
name: "Ambient Temperature"
name: Ambient Temperature
script:
- id: automation_test
@@ -342,7 +345,7 @@ script:
- repeat:
count: 5
then:
- logger.log: "looping!"
- logger.log: looping!
switch:
- platform: modbus_controller