Add OpenTherm component (part 3: rest of the sensors) (#7676)
Co-authored-by: FreeBear <freebear@tuxcnc.org> Co-authored-by: FreeBear-nc <67865163+FreeBear-nc@users.noreply.github.com> Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
This commit is contained in:
@@ -12,10 +12,41 @@ opentherm:
|
||||
cooling_enable: false
|
||||
otc_active: false
|
||||
ch2_active: true
|
||||
t_room: boiler_sensor
|
||||
summer_mode_active: true
|
||||
dhw_block: true
|
||||
sync_mode: true
|
||||
|
||||
output:
|
||||
- platform: opentherm
|
||||
t_set:
|
||||
id: t_set
|
||||
min_value: 20
|
||||
auto_max_value: true
|
||||
zero_means_zero: true
|
||||
t_set_ch2:
|
||||
id: t_set_ch2
|
||||
min_value: 20
|
||||
max_value: 40
|
||||
zero_means_zero: true
|
||||
|
||||
number:
|
||||
- platform: opentherm
|
||||
cooling_control:
|
||||
name: "Boiler Cooling control signal"
|
||||
t_dhw_set:
|
||||
name: "Boiler DHW Setpoint"
|
||||
max_t_set:
|
||||
name: "Boiler Max Setpoint"
|
||||
t_room_set:
|
||||
name: "Boiler Room Setpoint"
|
||||
t_room_set_ch2:
|
||||
name: "Boiler Room Setpoint CH2"
|
||||
max_rel_mod_level:
|
||||
name: "Maximum relative modulation level"
|
||||
otc_hc_ratio:
|
||||
name: "OTC heat curve ratio"
|
||||
|
||||
sensor:
|
||||
- platform: opentherm
|
||||
rel_mod_level:
|
||||
@@ -25,6 +56,7 @@ sensor:
|
||||
dhw_flow_rate:
|
||||
name: "Boiler Water flow rate in DHW circuit"
|
||||
t_boiler:
|
||||
id: "boiler_sensor"
|
||||
name: "Boiler water temperature"
|
||||
t_dhw:
|
||||
name: "Boiler DHW temperature"
|
||||
@@ -74,3 +106,55 @@ sensor:
|
||||
name: "OTC heat curve ratio upper bound"
|
||||
otc_hc_ratio_lb:
|
||||
name: "OTC heat curve ratio lower bound"
|
||||
|
||||
binary_sensor:
|
||||
- platform: opentherm
|
||||
fault_indication:
|
||||
name: "Boiler Fault indication"
|
||||
ch_active:
|
||||
name: "Boiler Central Heating active"
|
||||
dhw_active:
|
||||
name: "Boiler Domestic Hot Water active"
|
||||
flame_on:
|
||||
name: "Boiler Flame on"
|
||||
cooling_active:
|
||||
name: "Boiler Cooling active"
|
||||
ch2_active:
|
||||
name: "Boiler Central Heating 2 active"
|
||||
diagnostic_indication:
|
||||
name: "Boiler Diagnostic event"
|
||||
dhw_present:
|
||||
name: "Boiler DHW present"
|
||||
control_type_on_off:
|
||||
name: "Boiler Control type is on/off"
|
||||
cooling_supported:
|
||||
name: "Boiler Cooling supported"
|
||||
dhw_storage_tank:
|
||||
name: "Boiler DHW storage tank"
|
||||
controller_pump_control_allowed:
|
||||
name: "Boiler Controller pump control allowed"
|
||||
ch2_present:
|
||||
name: "Boiler CH2 present"
|
||||
dhw_setpoint_transfer_enabled:
|
||||
name: "Boiler DHW setpoint transfer enabled"
|
||||
max_ch_setpoint_transfer_enabled:
|
||||
name: "Boiler CH maximum setpoint transfer enabled"
|
||||
dhw_setpoint_rw:
|
||||
name: "Boiler DHW setpoint read/write"
|
||||
max_ch_setpoint_rw:
|
||||
name: "Boiler CH maximum setpoint read/write"
|
||||
|
||||
switch:
|
||||
- platform: opentherm
|
||||
ch_enable:
|
||||
name: "Boiler Central Heating enabled"
|
||||
restore_mode: RESTORE_DEFAULT_ON
|
||||
dhw_enable:
|
||||
name: "Boiler Domestic Hot Water enabled"
|
||||
cooling_enable:
|
||||
name: "Boiler Cooling enabled"
|
||||
restore_mode: ALWAYS_OFF
|
||||
otc_active:
|
||||
name: "Boiler Outside temperature compensation active"
|
||||
ch2_active:
|
||||
name: "Boiler Central Heating 2 active"
|
||||
|