Add OpenTherm component (part 3: rest of the sensors) (#7676)

Co-authored-by: FreeBear <freebear@tuxcnc.org>
Co-authored-by: FreeBear-nc <67865163+FreeBear-nc@users.noreply.github.com>
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
This commit is contained in:
Oleg Tarasov
2024-11-12 06:19:42 +03:00
committed by GitHub
parent a2dccc4730
commit 58d028ac13
22 changed files with 1128 additions and 11 deletions

View File

@@ -12,10 +12,41 @@ opentherm:
cooling_enable: false
otc_active: false
ch2_active: true
t_room: boiler_sensor
summer_mode_active: true
dhw_block: true
sync_mode: true
output:
- platform: opentherm
t_set:
id: t_set
min_value: 20
auto_max_value: true
zero_means_zero: true
t_set_ch2:
id: t_set_ch2
min_value: 20
max_value: 40
zero_means_zero: true
number:
- platform: opentherm
cooling_control:
name: "Boiler Cooling control signal"
t_dhw_set:
name: "Boiler DHW Setpoint"
max_t_set:
name: "Boiler Max Setpoint"
t_room_set:
name: "Boiler Room Setpoint"
t_room_set_ch2:
name: "Boiler Room Setpoint CH2"
max_rel_mod_level:
name: "Maximum relative modulation level"
otc_hc_ratio:
name: "OTC heat curve ratio"
sensor:
- platform: opentherm
rel_mod_level:
@@ -25,6 +56,7 @@ sensor:
dhw_flow_rate:
name: "Boiler Water flow rate in DHW circuit"
t_boiler:
id: "boiler_sensor"
name: "Boiler water temperature"
t_dhw:
name: "Boiler DHW temperature"
@@ -74,3 +106,55 @@ sensor:
name: "OTC heat curve ratio upper bound"
otc_hc_ratio_lb:
name: "OTC heat curve ratio lower bound"
binary_sensor:
- platform: opentherm
fault_indication:
name: "Boiler Fault indication"
ch_active:
name: "Boiler Central Heating active"
dhw_active:
name: "Boiler Domestic Hot Water active"
flame_on:
name: "Boiler Flame on"
cooling_active:
name: "Boiler Cooling active"
ch2_active:
name: "Boiler Central Heating 2 active"
diagnostic_indication:
name: "Boiler Diagnostic event"
dhw_present:
name: "Boiler DHW present"
control_type_on_off:
name: "Boiler Control type is on/off"
cooling_supported:
name: "Boiler Cooling supported"
dhw_storage_tank:
name: "Boiler DHW storage tank"
controller_pump_control_allowed:
name: "Boiler Controller pump control allowed"
ch2_present:
name: "Boiler CH2 present"
dhw_setpoint_transfer_enabled:
name: "Boiler DHW setpoint transfer enabled"
max_ch_setpoint_transfer_enabled:
name: "Boiler CH maximum setpoint transfer enabled"
dhw_setpoint_rw:
name: "Boiler DHW setpoint read/write"
max_ch_setpoint_rw:
name: "Boiler CH maximum setpoint read/write"
switch:
- platform: opentherm
ch_enable:
name: "Boiler Central Heating enabled"
restore_mode: RESTORE_DEFAULT_ON
dhw_enable:
name: "Boiler Domestic Hot Water enabled"
cooling_enable:
name: "Boiler Cooling enabled"
restore_mode: ALWAYS_OFF
otc_active:
name: "Boiler Outside temperature compensation active"
ch2_active:
name: "Boiler Central Heating 2 active"