mirror of
				https://github.com/esphome/esphome.git
				synced 2025-10-30 06:33:51 +00:00 
			
		
		
		
	Add ENS210 Humidity & Temperature sensor component (#2942)
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
This commit is contained in:
		| @@ -60,6 +60,7 @@ esphome/components/dht/* @OttoWinter | ||||
| esphome/components/ds1307/* @badbadc0ffee | ||||
| esphome/components/dsmr/* @glmnet @zuidwijk | ||||
| esphome/components/ektf2232/* @jesserockz | ||||
| esphome/components/ens210/* @itn3rd77 | ||||
| esphome/components/esp32/* @esphome/core | ||||
| esphome/components/esp32_ble/* @jesserockz | ||||
| esphome/components/esp32_ble_server/* @jesserockz | ||||
|   | ||||
							
								
								
									
										0
									
								
								esphome/components/ens210/__init__.py
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										0
									
								
								esphome/components/ens210/__init__.py
									
									
									
									
									
										Normal file
									
								
							
							
								
								
									
										230
									
								
								esphome/components/ens210/ens210.cpp
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										230
									
								
								esphome/components/ens210/ens210.cpp
									
									
									
									
									
										Normal file
									
								
							| @@ -0,0 +1,230 @@ | ||||
| // ENS210 relative humidity and temperature sensor with I2C interface from ScioSense | ||||
| // | ||||
| // Datasheet: https://www.sciosense.com/wp-content/uploads/2021/01/ENS210.pdf | ||||
| // | ||||
| // Implementation based on: | ||||
| //   https://github.com/maarten-pennings/ENS210 | ||||
| //   https://github.com/sciosense/ENS210_driver | ||||
|  | ||||
| #include "ens210.h" | ||||
| #include "esphome/core/log.h" | ||||
| #include "esphome/core/hal.h" | ||||
|  | ||||
| namespace esphome { | ||||
| namespace ens210 { | ||||
|  | ||||
| static const char *const TAG = "ens210"; | ||||
|  | ||||
| // ENS210 chip constants | ||||
| static const uint8_t ENS210_BOOTING_MS = 2;  // Booting time in ms (also after reset, or going to high power) | ||||
| static const uint8_t ENS210_SINGLE_MEASURMENT_CONVERSION_TIME_MS = | ||||
|     130;                                        // Conversion time in ms for single shot T/H measurement | ||||
| static const uint16_t ENS210_PART_ID = 0x0210;  // The expected part id of the ENS210 | ||||
|  | ||||
| // Addresses of the ENS210 registers | ||||
| static const uint8_t ENS210_REGISTER_PART_ID = 0x00; | ||||
| static const uint8_t ENS210_REGISTER_UID = 0x04; | ||||
| static const uint8_t ENS210_REGISTER_SYS_CTRL = 0x10; | ||||
| static const uint8_t ENS210_REGISTER_SYS_STAT = 0x11; | ||||
| static const uint8_t ENS210_REGISTER_SENS_RUN = 0x21; | ||||
| static const uint8_t ENS210_REGISTER_SENS_START = 0x22; | ||||
| static const uint8_t ENS210_REGISTER_SENS_STOP = 0x23; | ||||
| static const uint8_t ENS210_REGISTER_SENS_STAT = 0x24; | ||||
| static const uint8_t ENS210_REGISTER_T_VAL = 0x30; | ||||
| static const uint8_t ENS210_REGISTER_H_VAL = 0x33; | ||||
|  | ||||
| // CRC-7 constants | ||||
| static const uint8_t CRC7_WIDTH = 7;    // A 7 bits CRC has polynomial of 7th order, which has 8 terms | ||||
| static const uint8_t CRC7_POLY = 0x89;  // The 8 coefficients of the polynomial | ||||
| static const uint8_t CRC7_IVEC = 0x7F;  // Initial vector has all 7 bits high | ||||
|  | ||||
| // Payload data constants | ||||
| static const uint8_t DATA7_WIDTH = 17; | ||||
| static const uint32_t DATA7_MASK = ((1UL << DATA7_WIDTH) - 1);  // 0b 0 1111 1111 1111 1111 | ||||
| static const uint32_t DATA7_MSB = (1UL << (DATA7_WIDTH - 1));   // 0b 1 0000 0000 0000 0000 | ||||
|  | ||||
| // Converts a status to a human readable string | ||||
| static const LogString *ens210_status_to_human(int status) { | ||||
|   switch (status) { | ||||
|     case ENS210Component::ENS210_STATUS_I2C_ERROR: | ||||
|       return LOG_STR("I2C error - communication with ENS210 failed!"); | ||||
|     case ENS210Component::ENS210_STATUS_CRC_ERROR: | ||||
|       return LOG_STR("CRC error"); | ||||
|     case ENS210Component::ENS210_STATUS_INVALID: | ||||
|       return LOG_STR("Invalid data"); | ||||
|     case ENS210Component::ENS210_STATUS_OK: | ||||
|       return LOG_STR("Status OK"); | ||||
|     case ENS210Component::ENS210_WRONG_CHIP_ID: | ||||
|       return LOG_STR("ENS210 has wrong chip ID! Is it a ENS210?"); | ||||
|     default: | ||||
|       return LOG_STR("Unknown"); | ||||
|   } | ||||
| } | ||||
|  | ||||
| // Compute the CRC-7 of 'value' (should only have 17 bits) | ||||
| // https://en.wikipedia.org/wiki/Cyclic_redundancy_check#Computation | ||||
| static uint32_t crc7(uint32_t value) { | ||||
|   // Setup polynomial | ||||
|   uint32_t polynomial = CRC7_POLY; | ||||
|   // Align polynomial with data | ||||
|   polynomial = polynomial << (DATA7_WIDTH - CRC7_WIDTH - 1); | ||||
|   // Loop variable (indicates which bit to test, start with highest) | ||||
|   uint32_t bit = DATA7_MSB; | ||||
|   // Make room for CRC value | ||||
|   value = value << CRC7_WIDTH; | ||||
|   bit = bit << CRC7_WIDTH; | ||||
|   polynomial = polynomial << CRC7_WIDTH; | ||||
|   // Insert initial vector | ||||
|   value |= CRC7_IVEC; | ||||
|   // Apply division until all bits done | ||||
|   while (bit & (DATA7_MASK << CRC7_WIDTH)) { | ||||
|     if (bit & value) | ||||
|       value ^= polynomial; | ||||
|     bit >>= 1; | ||||
|     polynomial >>= 1; | ||||
|   } | ||||
|   return value; | ||||
| } | ||||
|  | ||||
| void ENS210Component::setup() { | ||||
|   ESP_LOGCONFIG(TAG, "Setting up ENS210..."); | ||||
|   uint8_t data[2]; | ||||
|   uint16_t part_id = 0; | ||||
|   // Reset | ||||
|   if (!this->write_byte(ENS210_REGISTER_SYS_CTRL, 0x80)) { | ||||
|     this->write_byte(ENS210_REGISTER_SYS_CTRL, 0x80); | ||||
|     this->error_code_ = ENS210_STATUS_I2C_ERROR; | ||||
|     this->mark_failed(); | ||||
|     return; | ||||
|   } | ||||
|   // Wait to boot after reset | ||||
|   delay(ENS210_BOOTING_MS); | ||||
|   // Must disable low power to read PART_ID | ||||
|   if (!set_low_power_(false)) { | ||||
|     // Try to go back to default mode (low power enabled) | ||||
|     set_low_power_(true); | ||||
|     this->error_code_ = ENS210_STATUS_I2C_ERROR; | ||||
|     this->mark_failed(); | ||||
|     return; | ||||
|   } | ||||
|   // Read the PART_ID | ||||
|   if (!this->read_bytes(ENS210_REGISTER_PART_ID, data, 2)) { | ||||
|     // Try to go back to default mode (low power enabled) | ||||
|     set_low_power_(true); | ||||
|     this->error_code_ = ENS210_STATUS_I2C_ERROR; | ||||
|     this->mark_failed(); | ||||
|     return; | ||||
|   } | ||||
|   // Pack bytes into partid | ||||
|   part_id = data[1] * 256U + data[0] * 1U; | ||||
|   // Check expected part id of the ENS210 | ||||
|   if (part_id != ENS210_PART_ID) { | ||||
|     this->error_code_ = ENS210_WRONG_CHIP_ID; | ||||
|     this->mark_failed(); | ||||
|   } | ||||
|   // Set default power mode (low power enabled) | ||||
|   set_low_power_(true); | ||||
| } | ||||
|  | ||||
| void ENS210Component::dump_config() { | ||||
|   ESP_LOGCONFIG(TAG, "ENS210:"); | ||||
|   LOG_I2C_DEVICE(this); | ||||
|   if (this->is_failed()) { | ||||
|     ESP_LOGE(TAG, "%s", LOG_STR_ARG(ens210_status_to_human(this->error_code_))); | ||||
|   } | ||||
|   LOG_UPDATE_INTERVAL(this); | ||||
|   LOG_SENSOR("  ", "Temperature", this->temperature_sensor_); | ||||
|   LOG_SENSOR("  ", "Humidity", this->humidity_sensor_); | ||||
| } | ||||
|  | ||||
| float ENS210Component::get_setup_priority() const { return setup_priority::DATA; } | ||||
|  | ||||
| void ENS210Component::update() { | ||||
|   // Execute a single measurement | ||||
|   if (!this->write_byte(ENS210_REGISTER_SENS_RUN, 0x00)) { | ||||
|     ESP_LOGE(TAG, "Starting single measurement failed!"); | ||||
|     this->status_set_warning(); | ||||
|     return; | ||||
|   } | ||||
|   // Trigger measurement | ||||
|   if (!this->write_byte(ENS210_REGISTER_SENS_START, 0x03)) { | ||||
|     ESP_LOGE(TAG, "Trigger of measurement failed!"); | ||||
|     this->status_set_warning(); | ||||
|     return; | ||||
|   } | ||||
|   // Wait for measurement to complete | ||||
|   this->set_timeout("data", uint32_t(ENS210_SINGLE_MEASURMENT_CONVERSION_TIME_MS), [this]() { | ||||
|     int temperature_data, temperature_status, humidity_data, humidity_status; | ||||
|     uint8_t data[6]; | ||||
|     uint32_t h_val_data, t_val_data; | ||||
|     // Set default status for early bail out | ||||
|     temperature_status = ENS210_STATUS_I2C_ERROR; | ||||
|     humidity_status = ENS210_STATUS_I2C_ERROR; | ||||
|  | ||||
|     // Read T_VAL and H_VAL | ||||
|     if (!this->read_bytes(ENS210_REGISTER_T_VAL, data, 6)) { | ||||
|       ESP_LOGE(TAG, "Communication with ENS210 failed!"); | ||||
|       this->status_set_warning(); | ||||
|       return; | ||||
|     } | ||||
|     // Pack bytes for humidity | ||||
|     h_val_data = (uint32_t)((uint32_t) data[5] << 16 | (uint32_t) data[4] << 8 | (uint32_t) data[3]); | ||||
|     // Extract humidity data and update the status | ||||
|     extract_measurement_(h_val_data, &humidity_data, &humidity_status); | ||||
|  | ||||
|     if (humidity_status == ENS210_STATUS_OK) { | ||||
|       if (this->humidity_sensor_ != nullptr) { | ||||
|         float humidity = (humidity_data & 0xFFFF) / 512.0; | ||||
|         this->humidity_sensor_->publish_state(humidity); | ||||
|       } | ||||
|     } else { | ||||
|       ESP_LOGW(TAG, "Humidity status failure: %s", LOG_STR_ARG(ens210_status_to_human(humidity_status))); | ||||
|       this->status_set_warning(); | ||||
|       return; | ||||
|     } | ||||
|     // Pack bytes for temperature | ||||
|     t_val_data = (uint32_t)((uint32_t) data[2] << 16 | (uint32_t) data[1] << 8 | (uint32_t) data[0]); | ||||
|     // Extract temperature data and update the status | ||||
|     extract_measurement_(t_val_data, &temperature_data, &temperature_status); | ||||
|  | ||||
|     if (temperature_status == ENS210_STATUS_OK) { | ||||
|       if (this->temperature_sensor_ != nullptr) { | ||||
|         // Temperature in Celsius | ||||
|         float temperature = (temperature_data & 0xFFFF) / 64.0 - 27315L / 100.0; | ||||
|         this->temperature_sensor_->publish_state(temperature); | ||||
|       } | ||||
|     } else { | ||||
|       ESP_LOGW(TAG, "Temperature status failure: %s", LOG_STR_ARG(ens210_status_to_human(temperature_status))); | ||||
|     } | ||||
|   }); | ||||
| } | ||||
|  | ||||
| // Extracts measurement 'data' and 'status' from a 'val' obtained from measurment. | ||||
| void ENS210Component::extract_measurement_(uint32_t val, int *data, int *status) { | ||||
|   *data = (val >> 0) & 0xffff; | ||||
|   int valid = (val >> 16) & 0x1; | ||||
|   uint32_t crc = (val >> 17) & 0x7f; | ||||
|   uint32_t payload = (val >> 0) & 0x1ffff; | ||||
|   // Check CRC | ||||
|   uint8_t crc_ok = crc7(payload) == crc; | ||||
|  | ||||
|   if (!crc_ok) { | ||||
|     *status = ENS210_STATUS_CRC_ERROR; | ||||
|   } else if (!valid) { | ||||
|     *status = ENS210_STATUS_INVALID; | ||||
|   } else { | ||||
|     *status = ENS210_STATUS_OK; | ||||
|   } | ||||
| } | ||||
|  | ||||
| // Sets ENS210 to low (true) or high (false) power. Returns false on I2C problems. | ||||
| bool ENS210Component::set_low_power_(bool enable) { | ||||
|   uint8_t low_power_cmd = enable ? 0x01 : 0x00; | ||||
|   ESP_LOGD(TAG, "Enable low power: %s", enable ? "true" : "false"); | ||||
|   bool result = this->write_byte(ENS210_REGISTER_SYS_CTRL, low_power_cmd); | ||||
|   delay(ENS210_BOOTING_MS); | ||||
|   return result; | ||||
| } | ||||
|  | ||||
| }  // namespace ens210 | ||||
| }  // namespace esphome | ||||
							
								
								
									
										39
									
								
								esphome/components/ens210/ens210.h
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										39
									
								
								esphome/components/ens210/ens210.h
									
									
									
									
									
										Normal file
									
								
							| @@ -0,0 +1,39 @@ | ||||
| #pragma once | ||||
|  | ||||
| #include "esphome/core/component.h" | ||||
| #include "esphome/components/sensor/sensor.h" | ||||
| #include "esphome/components/i2c/i2c.h" | ||||
|  | ||||
| namespace esphome { | ||||
| namespace ens210 { | ||||
|  | ||||
| /// This class implements support for the ENS210 relative humidity and temperature i2c sensor. | ||||
| class ENS210Component : public PollingComponent, public i2c::I2CDevice { | ||||
|  public: | ||||
|   float get_setup_priority() const override; | ||||
|   void dump_config() override; | ||||
|   void setup() override; | ||||
|   void update() override; | ||||
|  | ||||
|   void set_humidity_sensor(sensor::Sensor *humidity_sensor) { humidity_sensor_ = humidity_sensor; } | ||||
|   void set_temperature_sensor(sensor::Sensor *temperature_sensor) { temperature_sensor_ = temperature_sensor; } | ||||
|  | ||||
|   enum ErrorCode { | ||||
|     ENS210_STATUS_OK = 0,     // The value was read, the CRC matches, and data is valid | ||||
|     ENS210_STATUS_INVALID,    // The value was read, the CRC matches, but the data is invalid (e.g. the measurement was | ||||
|                               // not yet finished) | ||||
|     ENS210_STATUS_CRC_ERROR,  // The value was read, but the CRC over the payload (valid and data) does not match | ||||
|     ENS210_STATUS_I2C_ERROR,  // There was an I2C communication error | ||||
|     ENS210_WRONG_CHIP_ID      // The read PART_ID is not the expected part id of the ENS210 | ||||
|   } error_code_{ENS210_STATUS_OK}; | ||||
|  | ||||
|  protected: | ||||
|   bool set_low_power_(bool enable); | ||||
|   void extract_measurement_(uint32_t val, int *data, int *status); | ||||
|  | ||||
|   sensor::Sensor *temperature_sensor_; | ||||
|   sensor::Sensor *humidity_sensor_; | ||||
| }; | ||||
|  | ||||
| }  // namespace ens210 | ||||
| }  // namespace esphome | ||||
							
								
								
									
										58
									
								
								esphome/components/ens210/sensor.py
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										58
									
								
								esphome/components/ens210/sensor.py
									
									
									
									
									
										Normal file
									
								
							| @@ -0,0 +1,58 @@ | ||||
| import esphome.codegen as cg | ||||
| import esphome.config_validation as cv | ||||
| from esphome.components import i2c, sensor | ||||
| from esphome.const import ( | ||||
|     CONF_HUMIDITY, | ||||
|     CONF_ID, | ||||
|     CONF_TEMPERATURE, | ||||
|     DEVICE_CLASS_HUMIDITY, | ||||
|     DEVICE_CLASS_TEMPERATURE, | ||||
|     STATE_CLASS_MEASUREMENT, | ||||
|     UNIT_CELSIUS, | ||||
|     UNIT_PERCENT, | ||||
| ) | ||||
|  | ||||
| CODEOWNERS = ["@itn3rd77"] | ||||
| DEPENDENCIES = ["i2c"] | ||||
|  | ||||
| ens210_ns = cg.esphome_ns.namespace("ens210") | ||||
|  | ||||
| ENS210Component = ens210_ns.class_( | ||||
|     "ENS210Component", cg.PollingComponent, i2c.I2CDevice | ||||
| ) | ||||
|  | ||||
| CONFIG_SCHEMA = ( | ||||
|     cv.Schema( | ||||
|         { | ||||
|             cv.GenerateID(): cv.declare_id(ENS210Component), | ||||
|             cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema( | ||||
|                 unit_of_measurement=UNIT_CELSIUS, | ||||
|                 accuracy_decimals=1, | ||||
|                 device_class=DEVICE_CLASS_TEMPERATURE, | ||||
|                 state_class=STATE_CLASS_MEASUREMENT, | ||||
|             ), | ||||
|             cv.Optional(CONF_HUMIDITY): sensor.sensor_schema( | ||||
|                 unit_of_measurement=UNIT_PERCENT, | ||||
|                 accuracy_decimals=1, | ||||
|                 device_class=DEVICE_CLASS_HUMIDITY, | ||||
|                 state_class=STATE_CLASS_MEASUREMENT, | ||||
|             ), | ||||
|         } | ||||
|     ) | ||||
|     .extend(cv.polling_component_schema("60s")) | ||||
|     .extend(i2c.i2c_device_schema(0x43)) | ||||
| ) | ||||
|  | ||||
|  | ||||
| async def to_code(config): | ||||
|     var = cg.new_Pvariable(config[CONF_ID]) | ||||
|     await cg.register_component(var, config) | ||||
|     await i2c.register_i2c_device(var, config) | ||||
|  | ||||
|     if CONF_TEMPERATURE in config: | ||||
|         sens = await sensor.new_sensor(config[CONF_TEMPERATURE]) | ||||
|         cg.add(var.set_temperature_sensor(sens)) | ||||
|  | ||||
|     if CONF_HUMIDITY in config: | ||||
|         sens = await sensor.new_sensor(config[CONF_HUMIDITY]) | ||||
|         cg.add(var.set_humidity_sensor(sens)) | ||||
| @@ -547,11 +547,18 @@ sensor: | ||||
|   - platform: esp32_hall | ||||
|     name: "ESP32 Hall Sensor" | ||||
|     update_interval: 15s | ||||
|   - platform: hdc1080 | ||||
|   - platform: ens210 | ||||
|     temperature: | ||||
|       name: "Living Room Temperature 5" | ||||
|     humidity: | ||||
|       name: "Living Room Pressure 5" | ||||
|       name: 'Living Room Humidity 5' | ||||
|     update_interval: 15s | ||||
|     i2c_id: i2c_bus | ||||
|   - platform: hdc1080 | ||||
|     temperature: | ||||
|       name: 'Living Room Temperature 6' | ||||
|     humidity: | ||||
|       name: 'Living Room Humidity 5' | ||||
|     update_interval: 15s | ||||
|     i2c_id: i2c_bus | ||||
|   - platform: hlw8012 | ||||
|   | ||||
		Reference in New Issue
	