mirror of
				https://github.com/esphome/esphome.git
				synced 2025-10-31 07:03:55 +00:00 
			
		
		
		
	Add OpenTherm component (part 2.1: sensor platform) (#7529)
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
This commit is contained in:
		| @@ -1,3 +1,76 @@ | ||||
| api: | ||||
| wifi: | ||||
|   ap: | ||||
|     ssid: "Thermostat" | ||||
|     password: "MySecretThemostat" | ||||
|  | ||||
| opentherm: | ||||
|   in_pin: 1 | ||||
|   out_pin: 2 | ||||
|   in_pin: 4 | ||||
|   out_pin: 5 | ||||
|   ch_enable: true | ||||
|   dhw_enable: false | ||||
|   cooling_enable: false | ||||
|   otc_active: false | ||||
|   ch2_active: true | ||||
|   summer_mode_active: true | ||||
|   dhw_block: true | ||||
|   sync_mode: true | ||||
|  | ||||
| sensor: | ||||
|   - platform: opentherm | ||||
|     rel_mod_level: | ||||
|       name: "Boiler Relative modulation level" | ||||
|     ch_pressure: | ||||
|       name: "Boiler Water pressure in CH circuit" | ||||
|     dhw_flow_rate: | ||||
|       name: "Boiler Water flow rate in DHW circuit" | ||||
|     t_boiler: | ||||
|       name: "Boiler water temperature" | ||||
|     t_dhw: | ||||
|       name: "Boiler DHW temperature" | ||||
|     t_outside: | ||||
|       name: "Boiler Outside temperature" | ||||
|     t_ret: | ||||
|       name: "Boiler Return water temperature" | ||||
|     t_storage: | ||||
|       name: "Boiler Solar storage temperature" | ||||
|     t_collector: | ||||
|       name: "Boiler Solar collector temperature" | ||||
|     t_flow_ch2: | ||||
|       name: "Boiler Flow water temperature CH2 circuit" | ||||
|     t_dhw2: | ||||
|       name: "Boiler Domestic hot water temperature 2" | ||||
|     t_exhaust: | ||||
|       name: "Boiler Exhaust temperature" | ||||
|     burner_starts: | ||||
|       name: "Boiler Number of starts burner" | ||||
|     ch_pump_starts: | ||||
|       name: "Boiler Number of starts CH pump" | ||||
|     dhw_pump_valve_starts: | ||||
|       name: "Boiler Number of starts DHW pump/valve" | ||||
|     dhw_burner_starts: | ||||
|       name: "Boiler Number of starts burner during DHW mode" | ||||
|     burner_operation_hours: | ||||
|       name: "Boiler Number of hours that burner is in operation (i.e. flame on)" | ||||
|     ch_pump_operation_hours: | ||||
|       name: "Boiler Number of hours that CH pump has been running" | ||||
|     dhw_pump_valve_operation_hours: | ||||
|       name: "Boiler Number of hours that DHW pump has been running or DHW valve has been opened" | ||||
|     dhw_burner_operation_hours: | ||||
|       name: "Boiler Number of hours that burner is in operation during DHW mode" | ||||
|     t_dhw_set_ub: | ||||
|       name: "Boiler Upper bound for adjustement of DHW setpoint" | ||||
|     t_dhw_set_lb: | ||||
|       name: "Boiler Lower bound for adjustement of DHW setpoint" | ||||
|     max_t_set_ub: | ||||
|       name: "Boiler Upper bound for adjustement of max CH setpoint" | ||||
|     max_t_set_lb: | ||||
|       name: "Boiler Lower bound for adjustement of max CH setpoint" | ||||
|     t_dhw_set: | ||||
|       name: "Boiler Domestic hot water temperature setpoint" | ||||
|     max_t_set: | ||||
|       name: "Boiler Maximum allowable CH water setpoint" | ||||
|     otc_hc_ratio_ub: | ||||
|       name: "OTC heat curve ratio upper bound" | ||||
|     otc_hc_ratio_lb: | ||||
|       name: "OTC heat curve ratio lower bound" | ||||
|   | ||||
		Reference in New Issue
	
	Block a user