Javi Merino a82db5ed37 instrument/daq: Use clock boottime for the time column of the energy measurements
92e16ee873 ("instrument/daq: Add an explicit time column to the DAQ
measurements") added a time column to the DAQ measurements in order to
help correlate them with those of other collectors like
FtraceCollector.  Sadly, FTrace uses CLOCK_BOOTTIME instead of
CLOCK_MONOTONIC by default.  CLOCK_MONOTONIC is like CLOCK_BOOTTIME,
except that it stops when the device suspends, which is why I hadn't
spot the issue until now.

Switch to CLOCK_BOOTTIME to get the intended behaviour of the original
commit.