Javi Merino
a82db5ed37 instrument/daq: Use clock boottime for the time column of the energy measurements
92e16ee873 ("instrument/daq: Add an explicit time column to the DAQ
measurements") added a time column to the DAQ measurements in order to
help correlate them with those of other collectors like
FtraceCollector.  Sadly, FTrace uses CLOCK_BOOTTIME instead of
CLOCK_MONOTONIC by default.  CLOCK_MONOTONIC is like CLOCK_BOOTTIME,
except that it stops when the device suspends, which is why I hadn't
spot the issue until now.

Switch to CLOCK_BOOTTIME to get the intended behaviour of the original
commit.
2020-11-09 17:27:21 +00:00
Javi Merino
92e16ee873 instrument/daq: Add an explicit time column to the DAQ measurements
Add the monotonic clock time to the energy measurements to help
correlate the measurement with those of other collectors, like
FtraceCollector or LogcatCollector.
2020-03-02 14:48:46 +00:00
Sergei Trofimov
75ff31c6c7 readenergy: update table headers
Update CSV headers output by readenergy to match the corresponding
channel names. This will avoid needing to translate them afterwards.
2017-12-12 09:24:03 +00:00
Basil Eljuse
70d755d75b Mark inline function to be static to avoid link issues with GCC compiler 2017-08-01 08:28:47 +01:00
Basil Eljuse
dfc63a1cc0 readenergy: New flag to specify execution duration
- '-d' flag allow user to specify duration in sec
	- default is 0, which means run till user termination
	  signal is received
2017-03-16 08:07:11 +00:00
Sergei Trofimov
8300344f70 readenergy: fixing the Makefile
CFLAGS in the makefile were being specified incorrectly.

- the single quotes for forcing all options to be passed as a single
  token by the shell.
- Specifying -static and -lc via -Wl is not needed.
2017-03-15 12:58:50 +00:00
Chris Redpath
09915101d8 JunoEnergyInstrument: Provide INSTANTANEOUS interface
This allows clients to use the instrument more easily from their code
if they were previously used to using an HWMON-style interface.

In order to provide the measurement, the existing readenergy binary
is updated and changed so that if no output option is specified then
we just print the current values and exit.

Signed-off-by: Chris Redpath <chris.redpath@arm.com>
2015-12-15 17:09:55 +00:00
Sergei Trofimov
4e6afe960b devlib initial commit. 2015-10-09 09:30:04 +01:00